Impact of Slab Selection on Quantification of Choriocapillaris Flow Deficits by Optical Coherence Tomography Angiography
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- AMERICAN JOURNAL OF OPHTHALMOLOGY208 · pp.397 · 2019
- 피인용
- Web of Science 46Scopus 50
- FWCI (Scopus)
- 4.98
- JCR IF
- JCR 2018 4.483
- ISSN
- 0002-9394
저자
- 변익수제1저자Department of Ophthalmology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, South Korea
- Nassisi, MarcoDoheny Image Reading Center, Doheny Eye Institute, Los Angeles, California, USA
- Borrelli, EnricoDoheny Image Reading Center, Doheny Eye Institute, Los Angeles, California, USA
- Sadda, Srinivas R.교신저자Doheny Image Reading Center, Doheny Eye Institute, Los Angeles, California, USA
초록
PURPOSE: To assess the impact of slab selection on quantitative measurements of choriocapillaris (CC) flow deficits (FDs) using optical coherence tomography angiography (OCTA). DESIGN: Cross-sectional study. METHODS: Using a swept-source OCTA device, en face slabs to isolate the CC were first generated using the manufacturer's default setting: a 20-mu m-thick slab starting 29 mu m posterior to the centerline of the automatically segmented retinal pigment epithelium (RPE) band. The inner and/or outer borders were then adjusted by 2-mu m increments to generate CC slabs with a range of offsets relative to the center of the RPE band. FDs of the modified slabs were compared to that of the default slab. RESULTS: Twenty-seven eyes of healthy subjects (mean age, 42.0 years) were prospectively enrolled. FD % increased when the slab was shifted outward by >= 4 mu m and inward by 20 mu m (P < .05). Fifteen eyes (55.6%) showed large hypointense regions precluding quantification when the slab was shifted inward by 20 mu m. Those without hypointensity demonstrated a decrease in FD% when the slab was shifted inward by 10-18 mu m (P < .05). When modulating slab thickness, CC FD% increased and decreased when the slab thickness became thinner or thicker by >= 8 mu m, respectively (P < .05). CONCLUSIONS: Quantitative CC parameters may be significantly influenced by small differences in the slab selection. Slab close to the RPE can be susceptible to segmentation errors. These findings highlight the importance of accurate, precise, and consistent slab definition to reliably generate quantitative CC metrics from OCTA. (C) 2019 Elsevier Inc. All rights reserved.
키워드
SWEPT-SOURCEQUANTITATIVE ASSESSMENTRETINITIS-PIGMENTOSAIMAGELOCALIZATIONDEGENERATIONPRIMATE
식별자
- Scopus EID
- 2-s2.0-85073007005
- WoS UID
- 000504803400044



로그인
연구물 목록으로