본문 바로가기

Impact of Slab Selection on Quantification of Choriocapillaris Flow Deficits by Optical Coherence Tomography Angiography

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
AMERICAN JOURNAL OF OPHTHALMOLOGY208 · pp.397 · 2019
피인용
Web of Science 46Scopus 50
FWCI (Scopus)
4.98
JCR IF
JCR 2018 4.483
ISSN
0002-9394

저자

  1. 변익수제1저자Department of Ophthalmology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, South Korea
  2. Nassisi, MarcoDoheny Image Reading Center, Doheny Eye Institute, Los Angeles, California, USA
  3. Borrelli, EnricoDoheny Image Reading Center, Doheny Eye Institute, Los Angeles, California, USA
  4. Sadda, Srinivas R.교신저자Doheny Image Reading Center, Doheny Eye Institute, Los Angeles, California, USA

초록

PURPOSE: To assess the impact of slab selection on quantitative measurements of choriocapillaris (CC) flow deficits (FDs) using optical coherence tomography angiography (OCTA). DESIGN: Cross-sectional study. METHODS: Using a swept-source OCTA device, en face slabs to isolate the CC were first generated using the manufacturer's default setting: a 20-mu m-thick slab starting 29 mu m posterior to the centerline of the automatically segmented retinal pigment epithelium (RPE) band. The inner and/or outer borders were then adjusted by 2-mu m increments to generate CC slabs with a range of offsets relative to the center of the RPE band. FDs of the modified slabs were compared to that of the default slab. RESULTS: Twenty-seven eyes of healthy subjects (mean age, 42.0 years) were prospectively enrolled. FD % increased when the slab was shifted outward by >= 4 mu m and inward by 20 mu m (P < .05). Fifteen eyes (55.6%) showed large hypointense regions precluding quantification when the slab was shifted inward by 20 mu m. Those without hypointensity demonstrated a decrease in FD% when the slab was shifted inward by 10-18 mu m (P < .05). When modulating slab thickness, CC FD% increased and decreased when the slab thickness became thinner or thicker by >= 8 mu m, respectively (P < .05). CONCLUSIONS: Quantitative CC parameters may be significantly influenced by small differences in the slab selection. Slab close to the RPE can be susceptible to segmentation errors. These findings highlight the importance of accurate, precise, and consistent slab definition to reliably generate quantitative CC metrics from OCTA. (C) 2019 Elsevier Inc. All rights reserved.

키워드

SWEPT-SOURCEQUANTITATIVE ASSESSMENTRETINITIS-PIGMENTOSAIMAGELOCALIZATIONDEGENERATIONPRIMATE

식별자

Scopus EID
2-s2.0-85073007005
WoS UID
000504803400044