Three-Dimensional Evaluation on Accuracy of Conventional and Milled Gypsum Models and 3D Printed Photopolymer Models
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q2
- 저널
- MATERIALS12(21) · 2019
- 피인용
- Web of Science 55Scopus 59
- FWCI (Scopus)
- 1.62
- JCR IF
- JCR 2018 2.972
- ISSN
- 1996-1944
저자
- 최재원제1저자Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan 50612, Korea
- 안종주Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan 50612, Korea
- Son, KeunbadaDepartment of Dental Science, Graduate School, Kyungpook National University, 2177 Dalgubeol-daero, Jung-gu, Daegu 41940, Korea
- 허중보교신저자Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan 50612, Korea
초록
The aim of this study was to evaluate the accuracy of dental models fabricated by conventional, milling, and three-dimensional (3D) printing methods. A reference model with inlay, single crown, and three-unit fixed dental prostheses (FDP) preparations was prepared. Conventional gypsum models (CON) were manufactured from the conventional method. Digital impressions were obtained by intraoral scanner, which were converted into physical models such as milled gypsum models (MIL), stereolithography (SLA), and digital light processing (DLP) 3D printed photopolymer models (S3P and D3P). Models were extracted as standard triangulated language (STL) data by reference scanner. All STL data were superimposed by 3D analysis software and quantitative and qualitative analysis was performed using root mean square (RMS) values and color difference map. Statistical analyses were performed using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni's correction. For full arch, the RMS value of trueness and precision in CON was significantly smaller than in the other groups (p < 0.05/6 = 0.008), and there was no significant difference between S3P and D3P (p > 0.05/6 = 0.008). On the other hand, the RMS value of trueness in CON was significantly smaller than in the other groups for all prepared teeth (p < 0.05/6 = 0.008), and there was no significant difference between MIL and S3P (p > 0.05/6 = 0.008). In conclusion, conventional gypsum models showed better accuracy than digitally milled and 3D printed models.
키워드
dental modeltruenessprecisionmilling3D printingDENTAL MODELSDATA-ACQUISITIONIMPRESSIONSCASTSTRUENESSPRECISION
식별자
- Scopus EID
- 2-s2.0-85074637641
- WoS UID
- 000502798800040



로그인
연구물 목록으로