Separation detection of different circulating tumor cells in the blood using an electrochemical microfluidic channel modified with a lipid-bonded conducting polymer
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- BIOSENSORS & BIOELECTRONICS146 · 2019
- 피인용
- Web of Science 41Scopus 44
- FWCI (Scopus)
- 1.94
- JCR IF
- JCR 2018 9.518
- ISSN
- 0956-5663
저자
- 구루다트제1저자Department of Chemistry and Institute of BioPhysio Sensor Technology, Pusan National University, Busan, 46241, Republic of Korea
- 정새로미Department of Chemistry and Institute of BioPhysio Sensor Technology, Pusan National University, Busan, 46241, Republic of Korea
- 김정민Department of Chemistry and Institute of BioPhysio Sensor Technology, Pusan National University, Busan, 46241, Republic of Korea
- Kim, Moo-HyunDepartment of Cardiology, Dong-A University College of Medicine, Busan, 602-715, Republic of Korea
- Jung, Dong-KeunDepartment of Laboratory Medicine, Dong-A University College of Medicine, Busan, 602-715, Republic of Korea
- Han, Jin-YoungDepartment of Laboratory Medicine, Dong-A University College of Medicine, Busan, 602-715, Republic of Korea
- 심윤보교신저자Department of Chemistry and Institute of BioPhysio Sensor Technology, Pusan National University, Busan, 46241, Republic of Korea
초록
Different circulating tumor cells (CTCs) in blood were separated and detected through the decoration of anticancer drug on the target cells, along with chemical modification of the microfluidic channel walls using a lipid attached covalently to the conducting polymer. The working principle of the electrochemical microfluidic device was evaluated with experimental parameters affecting on the separation, in terms of mass and surface charge of target species, fluid flow rate, AC amplitude, and AC frequency. The separated CTCs were selectively detected via the oxidation of daunomycin adsorbed specifically at the cells using an electrochemical sensor installed at the channel end. The fluorescence microscopic examination also confirmed the separation of CTCs in the channel. To evaluate the reliability of the method, blood samples from 37 cancer patients were tested. The device was able to separate the CTCs with 92.0 +/- 0.5 % efficiency and 90.9% detection rate.
키워드
Circulating tumor cellsCancer detectionConducting polymerAmperometric separation detectionElectrochemical microfluidic deviceCANCER-PATIENTSENUMERATIONENRICHMENT
식별자
- Scopus EID
- 2-s2.0-85072780897
- WoS UID
- 000497250600008



로그인
연구물 목록으로