An experimental study on the flow and heat transfer of an impinging synthetic jet
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER144 · 2019
- 피인용
- Web of Science 42Scopus 53
- FWCI (Scopus)
- 1.29
- JCR IF
- JCR 2018 4.346
- ISSN
- 0017-9310
저자
- Xu, Yang제1저자Key Laboratory of Fluid Mechanics, Beijing University of Aeronautics and Astronautics, Ministry of Education, Beijing 100191, China
- 문찬희School of Mechanical Engineering, Pusan National University, Busan 46241, Republic of Korea
- Wang, Jin-JunKey Laboratory of Fluid Mechanics, Beijing University of Aeronautics and Astronautics, Ministry of Education, Beijing 100191, China
- Penyazkov, Oleg G.A.V. Luikov Heat and Mass Transfer Institute, Minsk 220072, Belarus
- 김경천교신저자School of Mechanical Engineering, Pusan National University, Busan 46241, Republic of Korea
초록
This study experimentally investigated the combined effects of the wall temperature (T-w0) and the orifice-to-wall distance (H/D) on the flow and heat transfer characteristics of an impinging synthetic jet. Thermographic phosphor thermometry (TPT) was used to measure the wall surface temperature, and the quantitative flow velocity was obtained using time-resolved particle image velocimetry (PIV). A cavity-diaphragm actuator was employed to generate a round synthetic jet to impinge onto a heated wall that was coated with Mg4FGeO6:Mn (MFG) for use as a temperature sensor. Three orifice-to-wall distances (H/D = 10, 15, and 20) and three wall temperatures (T-w0 = 60 degrees C, 90 degrees C, and 120 degrees C) were tested for comparison, whereas the the operating conditions of the incident synthetic jet were kept constant. It was found that the maximum temperature drop at the stagnation point could reach approximately 50 degrees C although the orifice-to-wall distance was relatively large in this study, which indicated a good cooling performance of the synthetic jet. The penetration of the wall shear layer played an important role on the cooling performance of the impinging synthetic jet. For a heated wall with high T wo , the enhanced buoyancy and thermal boundary layer resulted in the formation of a strong wall shear layer, which was more difficult for the impinging synthetic jet to affect or penetrate. For a large H/D, the vortex rings of the synthetic jet lose coherence completely before impacting the wall. Thus, they have no ability to penetrate the wall's shear layer to interact with it directly. As a result, the cooling performance of the impinging synthetic jet gradually decreased as both T-w0 and H/D increased. In particular, the maximum cooling effect by the synthetic jet impingement can achieve 64% of the theoretical maximum. (C) 2019 Elsevier Ltd. All rights reserved.
키워드
Impinging synthetic jetsThermographic phosphor thermometryPIVHeat transferFlow characteristicsCooling performanceTEMPERATURE MEASUREMENTSTHERMOGRAPHIC PHOSPHORSIMPINGEMENTEVOLUTIONTHERMOMETRYSEPARATIONCYLINDERLIFETIMEFIELDTIME