Automatic three-dimensional analysis of bone volume and quality change after maxillary sinus augmentation
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH21(6) · pp.1148 · 2019
- 피인용
- Web of Science 32Scopus 29
- FWCI (Scopus)
- 1.48
- JCR IF
- JCR 2018 3.212
- ISSN
- 1523-0899
저자
- 권진주제1저자Department of Oral and Maxillofacial Surgery, Pusan National University, Dental Research Institute, Yangsan, Korea
- 황재준Department of Oral and Maxillofacial Radiology, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
- 김용덕Department of Oral and Maxillofacial Surgery, Pusan National University, Dental Research Institute, Yangsan, Korea
- 신상훈Department of Oral and Maxillofacial Surgery, Pusan National University, Dental Research Institute, Yangsan, Korea
- 조봉혜Department of Oral and Maxillofacial Radiology, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
- 이재열교신저자Department of Oral and Maxillofacial Surgery, Pusan National University, Dental Research Institute, Yangsan, Korea
초록
IntroductionMaxillary sinus augmentation is a widely used surgical procedure to increase the bone volume before implant placement. In order to predict the stability of the implant, analysis of the change in bone volume and quality after a sinus graft procedure is necessary. The purpose of this study was to analyze the change in volume and quality of bone graft material after maxillary sinus augmentation using cone beam computed tomography (CBCT). Methods and MaterialsMaxillary sinus lift procedures using bovine bone materials (Bio-Oss, Geistrich, Swiss) without immediate implantation were performed at the Pusan National University Dental Hospital in 22 patients, from 2014 to 2017. CBCT images were captured before surgery (T1), a day after surgery (T2), and after 4 to 7 months at follow-up (T3). The T2 and T3 images were registered to the T1 image using histogram matching and intensity-based registration. A total of 30 sinuses were analyzed three-dimensionally (3-D), using self-made software MATLAB 2018a (MathWorks, Natick, Massachusetts). The volume and structural indices of the bone graft material were measured and analyzed. ResultsThe average volume of graft material showed a decrease, while the average gray value showed an increase during the follow-up period, but these changes were not statistically significant. The structural indices of the graft material after histogram matching showed a significant difference in homogeneity, connectivity, thickness, and roughness at the postoperative follow-up. ConclusionsThe volume and gray value showed no statistically significant changes after the maxillary sinus lift procedures. The results of this study show that structural analysis using histogram matching can be used as a promising tool to analyze the quality of graft materials.
키워드
BEAM COMPUTED-TOMOGRAPHYFLOOR AUGMENTATIONAUTOGENOUS BONEBOVINE BONERESORPTIONACCURACY
식별자
- Scopus EID
- 2-s2.0-85074642257
- WoS UID
- 000492418500001



로그인
연구물 목록으로