Effect of a synthetic osteoconductive bone graft substitute with zeta potential control (geneX (R) ds) in the treatment of intertrochanteric fracture: A single center experience of 115 consecutive proximal femoral nail antirotations
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q3Scopus Q2
- 저널
- JOURNAL OF ORTHOPAEDIC SCIENCE24(5) · pp.842 · 2019
- 피인용
- Web of Science 4Scopus 5
- FWCI (Scopus)
- 0.37
- JCR IF
- JCR 2018 1.257
- ISSN
- 0949-2658
저자
- 신원철제1저자Department of Orthopaedic Surgery, Pusan National University Yangsan Hospital, South Korea
- 장재훈Department of Orthopaedic Surgery, Bio-medical Research Institute, Pusan National University Hospital, South Korea
- 정재윤Department of Orthopaedic Surgery, Bio-medical Research Institute, Pusan National University Hospital, South Korea
- 서근택Department of Orthopaedic Surgery, Pusan National University Yangsan Hospital, South Korea
- 문남훈교신저자Department of Orthopaedic Surgery, Bio-medical Research Institute, Pusan National University Hospital, South Korea
초록
Introduction: Although various clinical applications of geneX (R) ds have been reported, no study has reported the clinical application of geneX (R) ds in osteoporotic hip fracture. The present study aimed to identify the clinical effect of the application of geneX (R) ds in elderly patients with intertrochanteric fracture treated using proximal femoral nail antirotation (PFNA). Materials and methods: From March 2014 to October 2017, 233 patients with intertrochanteric fracture (65 men and 168 women) were enrolled in this study. All patients received surgical treatment using PFNA. Patients were classified into two groups: those in whom geneX (R) ds which is synthetic osteo-conductive bone graft substitute with the unique property of Zeta Potential Control (ZPC (R)), was use, and those in whom it was not. We compared the preoperative details and surgical outcomes, including radiologic outcome (postoperative reduction, tip apex distance, sliding distance of the helical blade, union, and union time) and clinical outcomes (Harris Hip Score and the walking ability at the last follow-up) between the groups. Results: In patients with unstable fracture who achieved anatomical or extramedullary type of reduction, the average sliding distance at 1, 3, and 12 months was 4.9 mm, 7.5 mmm and 8.1 mm in the geneX (R) ds group and 7.5 mm, 10.8 mm, and 12.1 mm in the no geneX (R) ds group, respectively. There were significant differences in the sliding distance at 1, 3, and 12 months between these two groups. Conclusion: The use of this synthetic osteo-conductive bone graft substitute with zeta potential control may have positive effect on the controlled sliding of the helical blade and the healing of intertrochanteric fracture. (C) 2019 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
키워드
CALCIUM-PHOSPHATE CEMENTUNSTABLE TROCHANTERIC FRACTURESEDITOR ADVERSE-REACTIONSTRICALCIUM PHOSPHATEINTERNAL-FIXATIONTIBIAL PLATEAUHIP-FRACTURESAUGMENTATIONPFNAMULTICENTER
식별자
- Scopus EID
- 2-s2.0-85061321699
- WoS UID
- 000484844800015



로그인
연구물 목록으로