Development and evaluation of passive layer additive detector for stabilization in high-energy X-ray computerized tomography
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q3Scopus Q2
- 저널
- JOURNAL OF INSTRUMENTATION14 · 2019
- 피인용
- Web of Science 0Scopus 0
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2018 1.366
- ISSN
- 1748-0221
저자
- Han, M. J.제1저자Department of Radiation Oncology, Collage of Medicine, Inje University, Bokji-ro 75, Busan, Republic of Korea Name of Institute
- Shin, Y. H.Department of Radiation Oncology, Collage of Medicine, Inje University, Bokji-ro 75, Busan, Republic of Korea Name of Institute
- 정재훈Department of Research Institute for Convergence of Biomedical science and technology, Yangsan Hospital, Pusan National University, 20, Geumo-ro, Mulgeum-eup, Yangsan-si, Gyeongsangnam-do, Republic of Korea
- 허승욱Department of Research Institute for Convergence of Biomedical science and technology, Yangsan Hospital, Pusan National University, 20, Geumo-ro, Mulgeum-eup, Yangsan-si, Gyeongsangnam-do, Republic of Korea
- Oh, K. M.Radiation Equipment Research Division, Korea Atomic Energy Research Institute, Geumgu-gil 29, Jeongup, Republic of Korea
- Kim, K. H.Department of Radiation Oncology, Chungnam National University Hospital, Munhwa-ro 282, Jung-Gu, Daejeon, Republic of Korea
- Kim, J. Y.Departments of Radiation Oncology, Dongnam Institute of Radiological and Medical Sciences, 40, Jwadong-gil, Jangan-eup, Gijang-gun, Busan, Republic of Korea
- Oh, Y. K.Department of Radiation Oncology, Keimyung University Medical school, Darseong-ro 56, Jung-Gu, Daegu, Republic of Korea
- Cho, H. L.Department of Radiation Oncology, Busan Paik Hospital, Inje University, Bokji-ro 75, Busan, Republic of Korea
- Park, S. K.교신저자Department of Radiation Oncology, Busan Paik Hospital, Inje University, Bokji-ro 75, Busan, Republic of Korea
초록
To improve the image quality in cone-beam computerized tomography, a detector containing an insulator layer made of parylene-C was utilized in this study. In HgI2 sensors with photoconducting materials, we analyzed the signal based on the thickness of the parylene-C layer and leakage current. In addition, we tried to evaluate the reproducibility of Hgl(2) that decreases gradually based on the continuous X-ray study. For the signal-to-noise ratio, we evaluated the photocurrent/darkcurrent (P/D) ratio according to the reduction in the leakage current. Our results indicated a detector reproducibility of 0.82% for a parylene-layer thickness of 18 mu m, which represents an improvement of 0.43% over that of a "parylene-free" detector. Compared with the parylene-free sensors, the ones with a parylene layer displayed an approximately linear increase of the P/D ratio with increasing parylene layer thickness. For layers 18 or 20 mu m thick this ratio, indicative of image quality, exhibited an improvement of similar to 70 times or more in comparison to a parylene-free sensor.
키워드
Materials for solid-state detectorsSolid state detectorsX-ray detectorsPARYLENE C
식별자
- Scopus EID
- 2-s2.0-85072713141
- WoS UID
- 000482373600012



로그인
연구물 목록으로