본문 바로가기

Development and evaluation of passive layer additive detector for stabilization in high-energy X-ray computerized tomography

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q3Scopus Q2
피인용
Web of Science 0Scopus 0
FWCI (Scopus)
0
JCR IF
JCR 2018 1.366
ISSN
1748-0221

저자

  1. Han, M. J.제1저자Department of Radiation Oncology, Collage of Medicine, Inje University, Bokji-ro 75, Busan, Republic of Korea Name of Institute
  2. Shin, Y. H.Department of Radiation Oncology, Collage of Medicine, Inje University, Bokji-ro 75, Busan, Republic of Korea Name of Institute
  3. 정재훈Department of Research Institute for Convergence of Biomedical science and technology, Yangsan Hospital, Pusan National University, 20, Geumo-ro, Mulgeum-eup, Yangsan-si, Gyeongsangnam-do, Republic of Korea
  4. 허승욱Department of Research Institute for Convergence of Biomedical science and technology, Yangsan Hospital, Pusan National University, 20, Geumo-ro, Mulgeum-eup, Yangsan-si, Gyeongsangnam-do, Republic of Korea
  5. Oh, K. M.Radiation Equipment Research Division, Korea Atomic Energy Research Institute, Geumgu-gil 29, Jeongup, Republic of Korea
  6. Kim, K. H.Department of Radiation Oncology, Chungnam National University Hospital, Munhwa-ro 282, Jung-Gu, Daejeon, Republic of Korea
  7. Kim, J. Y.Departments of Radiation Oncology, Dongnam Institute of Radiological and Medical Sciences, 40, Jwadong-gil, Jangan-eup, Gijang-gun, Busan, Republic of Korea
  8. Oh, Y. K.Department of Radiation Oncology, Keimyung University Medical school, Darseong-ro 56, Jung-Gu, Daegu, Republic of Korea
  9. Cho, H. L.Department of Radiation Oncology, Busan Paik Hospital, Inje University, Bokji-ro 75, Busan, Republic of Korea
  10. Park, S. K.교신저자Department of Radiation Oncology, Busan Paik Hospital, Inje University, Bokji-ro 75, Busan, Republic of Korea

초록

To improve the image quality in cone-beam computerized tomography, a detector containing an insulator layer made of parylene-C was utilized in this study. In HgI2 sensors with photoconducting materials, we analyzed the signal based on the thickness of the parylene-C layer and leakage current. In addition, we tried to evaluate the reproducibility of Hgl(2) that decreases gradually based on the continuous X-ray study. For the signal-to-noise ratio, we evaluated the photocurrent/darkcurrent (P/D) ratio according to the reduction in the leakage current. Our results indicated a detector reproducibility of 0.82% for a parylene-layer thickness of 18 mu m, which represents an improvement of 0.43% over that of a "parylene-free" detector. Compared with the parylene-free sensors, the ones with a parylene layer displayed an approximately linear increase of the P/D ratio with increasing parylene layer thickness. For layers 18 or 20 mu m thick this ratio, indicative of image quality, exhibited an improvement of similar to 70 times or more in comparison to a parylene-free sensor.

키워드

Materials for solid-state detectorsSolid state detectorsX-ray detectorsPARYLENE C

식별자

Scopus EID
2-s2.0-85072713141
WoS UID
000482373600012