Image Quality and Radiation Dose in CT Venography Using Model-Based Iterative Reconstruction at 80 kVp versus Adaptive Statistical Iterative Reconstruction-V at 70 kVp

문서 유형
연구출판물 · 학술지 논문
등재
KCISCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
KOREAN JOURNAL OF RADIOLOGY20(7) · pp.1167 · 2019
피인용
Web of Science 19Scopus 22KCI 2
FWCI (Scopus)
1.1
JCR IF
JCR 2018 3.73
ISSN
1229-6929

저자

  1. 박찬규제1저자Department of Radiology, Pusan National University Yangsan Hospital, Yangsan, Korea;
  2. 추기석교신저자Department of Radiology, Pusan National University Yangsan Hospital, Yangsan, Korea;
  3. 김진혁Department of Radiology, Pusan National University Yangsan Hospital, Yangsan, Korea;
  4. 남경진Department of Radiology, Pusan National University Yangsan Hospital, Yangsan, Korea;
  5. 이지원ADepartment of Radiology, Pusan National University Hospital, Busan, Korea
  6. 김진유Department of Radiology, Pusan National University Hospital, Busan, Korea

초록

Objective: To compare the objective and subjective image quality indicators and radiation doses of computed tomography (CT) venography performed using model-based iterative reconstruction (MBIR) at 80 kVp and adaptive statistical iterative reconstruction (ASIR)-V at 70 kVp. Materials and Methods: Eighty-three patients who had undergone CT venography of the lower extremities with MBIR at 80 kVp (Group A; 21 men and 20 women; mean age, 55.5 years) or ASIR-V at 70 kVp (Group B; 18 men and 24 women; mean age, 57.3 years) were enrolled. Two radiologists retrospectively evaluated the objective (vascular enhancement, image noise, signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR]) and subjective (quantum mottle, delineation of contour, venous enhancement) image quality indicators at the inferior vena cava and femoral and popliteal veins. Clinical information, radiation dose, reconstruction time, and objective and subjective image quality indicators were compared between groups A and B. Results: Vascular enhancement, SNR, and CNR were significantly greater in Group B than in Group A (p <= 0.015). Image noise was significantly lower in Group B (p <= 0.021), and all subjective image quality indicators, except for delineation of vein contours, were significantly better in Group B (p <= 0.021). Mean reconstruction time was significantly shorter in Group B than in Group A (1 min 43 s vs. 131 min 1 s; p < 0.001). Clinical information and radiation dose were not significantly different between the two groups. Conclusion: CT venography using ASIR-V at 70 kVp was better than MBIR at 80 kVp in terms of image quality and reconstruction time at similar radiation doses.

키워드

CT venographyImage reconstructionASIR-VRadiation doseDeep vein thrombosisDEEP-VEIN THROMBOSISCOMPUTED-TOMOGRAPHY VENOGRAPHYFILTERED BACK-PROJECTIONTUBE-VOLTAGEABDOMINAL CTQUANTITATIVE-ANALYSISVASCULAR ENHANCEMENTREDUCED RADIATIONREDUCTIONANGIOGRAPHY