본문 바로가기

독립형 액화가스 저장탱크의 BOG 발생에 대한 실험적 분석

Experimental Analysis of Boil-Off Gas Occurrence in Independent Liquefied Gas Storage Tank

문서 유형
연구출판물 · 학술지 논문
등재
KCIKCI우수
저널
한국해양공학회지 (JOET)32(5) · pp.380 · 2018
피인용
KCI 3
ISSN
1225-0767

저자

  1. 차승주제1저자부산대학교
  2. 배진호부산대학교 조선해양공학과
  3. 이동하부산대학교
  4. 김태욱부산대학교
  5. 김슬기부산대학교
  6. 이제명교신저자부산대학교

초록

With the tightening of environmental regulations (i.e., IMO Tier III), natural gas (NG) has been spotlighted as an eco-friendly fuel with few air pollutants other than nitrogen oxides (NOx) and sulfur oxides (SOx). For reasons of economic efficiency, it is mainly stored and transported in a liquid state at -163 °C, which is a cryogenic temperature, using a liquefied gas storage tank. Accordingly, it is necessary to reduce the boil-off gas (BOG) occurrence due to the heat flow according to the temperature difference between the inside and outside of the storage tank. Therefore, in this study, a BOG measurement test on an independent-type storage tank made up of SUS304L was carried out. The test results showed the tendency for BOG occurrence according to the temperature under different filling ratios.

키워드

Independent type liquefied gas storage tank 독립형 액화가스 저장탱크Boil-off gas 자연기화가스Cryogenic 극저온Liquid cargo 액체화물Thermal analysis 열분석

식별자

KCI
ART002396985