본문 바로가기

Elimination efficiency of organic UV filters during ozonation and UV/H2O2 treatment of drinking water and wastewater effluent

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
CHEMOSPHERE230 · pp.248 · 2019
피인용
Web of Science 20Scopus 23
FWCI (Scopus)
0.85
JCR IF
JCR 2018 5.108
ISSN
0045-6535

저자

  1. 서창동제1저자Department of Bioenvironmental Energy, Pusan National University, Pusan, South Korea
  2. Shin, JaedonSchool of Earth Sciences and Environmental Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju, South Korea
  3. Lee, MinjuDepartment of Chemistry, University of Washington, Seattle, United States
  4. Lee, WoongbaeSchool of Earth Sciences and Environmental Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju, South Korea
  5. Yoom, HoonsikBusan Water Quality Institute, Busan, South Korea
  6. Son, HeejongBusan Water Quality Institute, Busan, South Korea
  7. 장성호Department of Bioenvironmental Energy, Pusan National University, Pusan, South Korea
  8. Lee, Yunho교신저자School of Earth Sciences and Environmental Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju, South Korea

초록

The efficiency of elimination of organic UV filters by ozonation and UV254nm/H2O2 processes was assessed and predicted in simulated treatments of sewage-impaired drinking water and wastewater effluent in bench-scale experiments. Second-order rate constants (k) for the reactions of the eight UV filters with ozone and center dot OH were determined by quantum chemical calculations and competition kinetics methods, respectively. The UV filters containing phenolic (ethylhexyl-salicylate, homosalate, and benzophenone-3) and olefinic moieties (4-methylbenzylidene-camphor, benzyl-cinnamate, and 2-ethylhexyl-4-methoxycinnamate) showed high ozone reactivity (k >= 8 x 10(4) M-1 s(-1) at pH 7), while those without such electron-rich moieties (isoamyl-benzoate and benzophenone) were ozone-refractory. All the UV filters showed high center dot OH reactivity (k >= 6.2 x 10(9) M-1 s(-1)). In concordance with the rate constant information, the phenolic and olefinic UV filters were efficiently eliminated by ozone treatment, requiring specific ozone doses of <0.5 mgO(3)/mgDOC for similar to 100% elimination. The UV filters were eliminated by <= 38% at a UV fluence of 1500 mi/cm(2) in the UV254nm-only treatment. Rapid photoisomerisation between the E and Z geometric isomers was observed for the olefinic UV filter, benzyl-cinnamate. The addition of H2O2 (10 mg/L) greatly enhanced the elimination of all UV filters, indicating that center dot OH was the main contributor to their elimination in the UV254nm/H2O2 treatment. A chemical kinetics approach developed previously for ozonation and UV/H2O2 processes was shown to predict the elimination of the UV filters in the tested water matrices reasonably well, demonstrating that the chemical kinetics method can be used for a priori prediction of micropollutant elimination in oxidative treatment processes for potable reuse of municipal wastewater effluents. (C) 2019 Elsevier Ltd. All rights reserved.

키워드

Organic UV filterMicropollutantOzoneUV/H2O2OH radicalQSARPERSONAL CARE PRODUCTSREACTION-KINETICSSURFACE WATERSMICROPOLLUTANT ELIMINATIONTRANSFORMATION PRODUCTSCONTAMINANT ABATEMENTECOLOGICAL RISKSAQUEOUS-SOLUTIONPREDICTIONOZONE

식별자

Scopus EID
2-s2.0-85066073852
WoS UID
000471736000027