Purpose: As the number of a small theater increases, managing safety will become a greater priority. However, it is reported that most small theaters in Korea are obsolete and the safety standards are not sufficient enough to cause accidents. Therefore, this study investigated the problems related to evacuation safety in small theaters. Method: This study investigated problems caused by the evacuation distance to the direct stairway, the width of the indoor passage, and obstacles in the use stage for the actual small theater. In this study, case studies were carried out through evacuation simulation to find ways to improve the problems caused by architectural design changes. Result: As a result of the simulation, the evacuation safety performance at the design stage was about 90 seconds difference in total evacuation time compared to the current use stage. In addition, evacuation was faster due to a 22% reduction in average cumulative waiting time as a result of design changes to improve bottlenecks. Therefore, it is necessary to review the safety performance in the use stage of the evacuation safety review, and it is considered necessary to establish the standard of the minimum corridor width in the room and to strengthen the standard application of the distance to the direct stairway.