본문 바로가기

Comparing the Diagnostic Accuracies of F-18 Fluorodeoxyglucose Positron Emission Tomography and Magnetic Resonance Imaging for the Detection of Spondylodiscitis

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
SPINE44(7) · pp.E414 · 2019
피인용
Web of Science 24Scopus 31
FWCI (Scopus)
0.98
JCR IF
JCR 2018 2.903
ISSN
0362-2436

저자

  1. 김성장제1저자Department of Nuclear Medicine BioMedical Research Institute for Convergence of Biomedical Science and Technology Pusan National University Yangsan Hospital Yangsan Republic of Korea
  2. 박경준† Department of Nuclear Medicine and Biomedical Research Institute Pusan National University Hospital Busan Republic of Korea
  3. 김근영† Department of Nuclear Medicine and Biomedical Research Institute Pusan National University Hospital Busan Republic of Korea
  4. 이정섭교신저자‡ Department of Orthopaedic Surgery BioMedical Research Institute Pusan National University Hospital Busan Republic of Korea.

초록

Study Design. A meta-analysis. Objective. The aim of this study was to compare the diagnostic accuracies of F-18 fluorodeoxyglucose (F-18 FDG) positron emission tomography (PET) and magnetic resonance imaging (MRI) for the detection of spondylodiscitis through a metaanalysis. Summary of Background Data. There is no meta-analysis study that compares the diagnostic accuracies of F-18 FDG PET and MRI for the detection of spondylodiscitis. Methods. The MEDLINE and EMBASE databases were searched from the earliest available date of indexing to January 10, 2018 for studies comparing the diagnostic performance F-18 FDG PET with that of MRI for the detection of spondylodiscitis. We determined the sensitivities and specificities across studies, calculated the positive and negative likelihood ratios (LRthorn and LR ), and constructed the summary receiver operating characteristic curves. Results. In the seven studies (212 patients) selected, the pooled sensitivity and specificity of F-18 FDG PET were 0.95 (95% confidence interval [ CI]: 0.87-0.98) and 0.88 (95% CI: 0.73-0.95), respectively. The LR syntheses showed an overall LRthorn of 7.6 (95% CI: 3.4-17.2) and LR of 0.05 (95% CI: 0.02-0.14). The pooled diagnostic odds ratio was 141 (95% CI: 44-444). The pooled sensitivity and specificity of MRI were 0.85 (95% CI: 0.65-0.95) and 0.66 (95% CI: 0.48-0.80), respectively. The LR syntheses showed an overall LRthorn of 2.5 (95% CI: 1.5-4.2) and LR of 0.22 (95% CI: 0.08-0.60). The pooled diagnostic odds ratio was 11 (95% CI: 3-42). In the meta-regression analysis, no variable was identified as the source of the study heterogeneity. Conclusion. The current meta-analysis shows that F-18 FDG PET has better diagnostic accuracy than MRI for the detection of spondylodiscitis. Further large multicenter studies would be necessary to substantiate the diagnostic accuracies of F-18 FDG PET and MRI for spondylodiscitis.

키워드

F-18 fluorodeoxyglucosemagnetic resonance imagingpositron emission tomography-computed tomographyspondylodiscitisVERTEBRAL OSTEOMYELITISFDG-PET/CTWORK-UPMETAANALYSISMRITOOLSPINEBIAS

식별자

Scopus EID
2-s2.0-85063251550
WoS UID
000467741800005