본문 바로가기

Clinical Practicability of a Newly Developed Real-time Digital Kymographic System

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q3Scopus Q1
저널
JOURNAL OF VOICE33(3) · pp.346 · 2019
피인용
Web of Science 3Scopus 3
FWCI (Scopus)
0.19
JCR IF
JCR 2018 1.453
ISSN
0892-1997

저자

  1. 이진춘제1저자Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University School of Medicine, Yangsan, Gyeongsangnam-do, South Korea
  2. 왕수건교신저자Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University School of Medicine, Yangsan, Gyeongsangnam-do, South Korea
  3. 성의숙Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University School of Medicine, Yangsan, Gyeongsangnam-do, South Korea
  4. 배인호Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University Yangsan Hospital, Yangsan, Gyeongsangnam-do, South Korea
  5. Kim, Seong-TaeDepartment of Speech-Language Pathology, Dongshin University, Naju, Jeollanam-do, South Korea
  6. 이연우Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University Hospital, Busan, South Korea

초록

Background. A digital kymogram shows real images of vocal fold vibration. However, DKG is difficult to use in clinical practice because the recorded image cannot be seen instantaneously after examination, as considerable encoding time is required to visualize a digital kymogram. In addition, frame-by frame analysis should be implemented to evaluate high-speed videoendoscopy data, but is time- and labor-intensive. Purpose. The purpose of the study was to validate the clinical practicability of a real-time multislice digital kymographic system developed by the authors. We analyzed the promptness and accuracy of the examination before and after intracordal injections in patients with unilateral vocal fold paralysis. Methods. To assess the clinical applicability of this system, six patients with unilateral vocal fold paralysis were selected. Real-time DKG was performed before and immediately after intracordal injection. We observed changes in the digital kymogram after the intracordal injection. Results. Using this system, 10 scanning lines and up to five vertical pixel row could be obtained in real time, and the maximum acquisition time for the DKG image was 10 seconds. A digital kymogram of the patients could be instantaneously acquired, and whether the intracordal injection was appropriate or not. Conclusion. This article is the first validation study after the development of the real-time multislice digital kymographic system. Our system may be a promising tool in clinical practice for immediate assessment of the vibratory patterns of the vocal cords. More research is necessary for further clinical validation.

키워드

Real-timeDigital kymographyIntracordal injectionVocal cordParalysisVOCAL FOLD VIBRATIONVIDEOKYMOGRAPHYFORM

식별자

Scopus EID
2-s2.0-85038809579
WoS UID