수평관 기포유동 실험 데이터를 이용한 3차원 2상유동 해석코드 CUPID 평가
ASSESSMENT OF THE THREE-DIMENSIONAL TWO-PHASE FLOW ANALYSIS CODE, CUPID USING HORIZONTAL BUBBLY FLOW EXPERIMENTS
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCI
- 저널
- 한국전산유체공학회지23(1) · pp.19 · 2018
- 피인용
- KCI 0
- ISSN
- 1598-6071
저자
초록
Bubbly flows may occur in horizontal pipes during an accident in a nuclear power plant. Horizontal bubbly flows are characterized by asymmetric distribution of main parameters, such as void fraction and velocity, and slip ratio less than 1. Thus, three-dimensional simulation capability is needed for horizontal bubbly flows. In this study, horizontal bubbly flows were simulated using the CUPID code. The model evaluation results showed that the particle based 2-fluid momentum equation simulated more physically reasonable slip ratio than standard 2-fluid momentum equation and the turbulent dispersion force was the most important factor in the prediction of void fraction. In the quantitative assessments, it was shown that the CUPID code predicted well the axial pressure drop within the error range of 10%. Also, the code estimated well axial development process of void fraction. However, it was found that the code can not simulate asymmetric distribution of flow parameters and phenomena which gas phase moves slower than liquid phase. To improve the prediction ability, the modification of turbulence model such as turbulent shear stress, bubble induced turbulence, and so on, or the additional term in momentum equation are needed.
키워드
수평관(Horizontal Pipe)기포 유동(Bubbly Flow) CUPID 코드(CUPID Code)입자기반 2-유체 운동량 방정식(Particle Based Two-Fluid Momentum Equation)
식별자
- KCI
- ART002329525



로그인