본문 바로가기

Diffusion-weighted Imaging of Invasive Breast Cancer: Relationship to Distant Metastasis-free Survival

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
RADIOLOGY291(2) · pp.299 · 2019
피인용
Web of Science 37Scopus 40
FWCI (Scopus)
1.8
JCR IF
JCR 2018 7.608
ISSN
0033-8419

저자

  1. 김진유제1저자교신저자Medical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, South Korea
  2. 김진주Department of Radiology, Pusan National University Hospital, Busan, South Korea
  3. 황보리Department of Radiology, Pusan National University Hospital, Busan, South Korea
  4. 강태우Busan Cancer Center, Pusan National University Hospital, Busan, South Korea
  5. 박희성Busan Cancer Center, Pusan National University Hospital, Busan, South Korea

초록

Background: Combined minimum apparent diffusion coefficient (ADC) and ADC difference value may improve the diagnostic performance of breast diffusion-weighted imaging (DWI) compared with mean ADC. Purpose: To investigate whether ADC parameters at DWI are associated with distant metastasis-free survival in women with invasive breast cancer. Materials and Methods: Between 2013 and 2014, 258 consecutive women (mean age 6 standard deviation, 50.9 years +/- 10.5; age range, 23-85 years) with newly diagnosed invasive breast cancer who underwent preoperative MRI with DWI were evaluated. All DWI examinations were retrospectively reviewed by two radiologists blinded to clinical information. The mean, minimum, and maximum ADCs were measured by manually placing regions of interest within the lesions, and the ADC difference value (the difference between minimum and maximum ADCs) was calculated to evaluate intratumoral heterogeneity. Cox proportional hazards models were used to determine the associations between ADC parameters and distant metastasis-free survival after adjustment for clinical-pathologic factors. Results: In 25 of the 258 women (9.7%), distant metastasis developed at a median follow-up of 51 months. The ADC difference value was higher in women with distant metastasis than in those without distant metastasis (mean, 0.743 x 10(-3) mm(2)/sec vs 0.566 x 10(-3) mm(2)/sec, respectively; P < .001). Multivariable Cox proportional hazards analysis showed that a higher ADC difference value (>0.698 x 10(-3) mm(2)/sec) (hazard ratio [HR], 4.5; 95% confidence interval [CI]: 2.0, 10.0; P < .001), presence of axillary node metastasis (HR, 3.3; 95% CI: 1.2, 9.3; P =.02), and estrogen receptor negativity (HR, 2.6; 95% CI: 1.2, 5.7; P =.02) were associated with poorer distant metastasis-free survival. Conclusion: A higher apparent diffusion coefficient difference value at diffusion-weighted imaging is associated with poorer distant metastasis-free survival of women with invasive breast cancer. (c) RSNA, 2019

키워드

PATHOLOGICAL PROGNOSTIC-FACTORSCARCINOMA IN-SITUTUMOR HETEROGENEITYCOEFFICIENTASSOCIATIONRECURRENCECOMPONENTSVALUES

식별자

Scopus EID
2-s2.0-85065038399
WoS UID
000466468000005