Tumor localization using radio-frequency identification clip marker: experimental results of an ex vivo porcine model

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
피인용
Web of Science 5Scopus 6
FWCI (Scopus)
0.55
JCR IF
JCR 2018 3.209
ISSN
0930-2794

저자

  1. 주환이제1저자School of Mechanical Engineering, Pusan National University, 63 BusanDaehak-Ro, GeumJeong-Gu, Busan, 46241, South Korea
  2. 이봉은Department of Gastroenterology, Medical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro, Seo-Gu, Busan, 602-739, South Korea
  3. 최창인Department of Surgery, Medical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro, Seo-Gu, Busan, 602-739, South Korea
  4. 김대환Department of Surgery, Medical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro, Seo-Gu, Busan, 602-739, South Korea
  5. 김광하Department of Gastroenterology, Medical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro, Seo-Gu, Busan, 602-739, South Korea
  6. 전태용Department of Surgery, Medical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro, Seo-Gu, Busan, 602-739, South Korea
  7. 김동헌Department of Surgery, Medical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro, Seo-Gu, Busan, 602-739, South Korea
  8. 안석영교신저자School of Mechanical Engineering, Pusan National University, 63 BusanDaehak-Ro, GeumJeong-Gu, Busan, 46241, South Korea

초록

PurposeWith the widespread use of minimally invasive surgery, tumor detection is becoming more difficult. We present the experimental results of a radio-frequency identification (RFID) lesion detection system in an ex vivo porcine model.MethodsThe efficacy and feasibility of a newly developed RFID lesion detection system were examined. It was applied to the stomach and colon of pigs weighing 40kg. The RFID clip was attached to the upper and lower mucosal sides of the stomach. Colon specimens with thin and thick walls were used. The clipped sites were marked on the serosa by a pin. The longest distance from the pin the RFID tag could be detected was measured 25 times in each direction.ResultsIn the upper gastric wall, the RFID tag detection distance was 4.50.9mm, 5.6 +/- 0.7mm, 12.5 +/- 0.7mm, and 5.3 +/- 0.5mm in the four directions, respectively (right, left, upper, and lower). In the antrum, the RFID tag detection distance was 5.8 +/- 0.7mm, 6.9 +/- 0.5mm, 5.6 +/- 0.5mm, and 3.7 +/- 0.5mm in the four directions. In the thin colon, the RFID tag detection distance was 6.3 +/- 0.5mm, 5.0 +/- 0.5mm, 9.7 +/- 0.7mm, and 6.4 +/- 0.4mm in the four directions. In the thick colon, the RFID tag detection distance was 3.5 +/- 0.8mm, 6.6 +/- 0.5mm, 8.4 +/- 0.6mm, and 9.8 +/- 0.5mm in the four directions. The area of detection was smallest for the antrum (83.7mm(2)) and similar for the other sites (150.6, 154.7 and 157.7mm(2) for the upper body, thin colon, and thick colon, respectively).Conclusionsp id=ParThe distance at which the RFID tag was detected was usually within 10mm. These results indicate the feasibility of the clinical application of the add-on clip and RFID tag as a marker for identifying the location of various gastrointestinal tumors.

키워드

Gastrointestinal tumorLesion detectionRadio-frequency identificationEndoscopic clipASSISTED DISTAL GASTRECTOMYLYMPH-NODE DISSECTIONGASTRIC-CANCER