The Feasibility of a Prototype Thyroidoscope for Gasless Transoral Endoscopic Thyroidectomy: A Preclinical Cadaver Study
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q3Scopus Q2
- 저널
- JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES29(7) · pp.953 · 2019
- 피인용
- Web of Science 7Scopus 10
- FWCI (Scopus)
- 0.82
- JCR IF
- JCR 2018 1.322
- ISSN
- 1092-6429
저자
- Park, Jun-Ook제1저자Department of Otolaryngology, Head and Neck Surgery, Catholic University College of Medicine, Seoul, Republic of Korea.
- 왕수건Department of Otorhinolaryngology, Head and Neck Surgery, Biomedical Research Institute, Pusan National University School of Medicine, Pusan National University Hospital, Busan, Republic of Korea.
- 박다희Department of Otorhinolaryngology, Head and Neck Surgery, Biomedical Research Institute, Pusan National University School of Medicine, Pusan National University Yangsan Hospital, Yangsan, Korea.
- 배인호Department of Otorhinolaryngology, Head and Neck Surgery, Pusan National University Yangsan Hospital, Yangsan, Korea.
- 이진춘Department of Otorhinolaryngology, Head and Neck Surgery, Biomedical Research Institute, Pusan National University School of Medicine, Pusan National University Yangsan Hospital, Yangsan, Korea.
- 이병주Department of Otorhinolaryngology, Head and Neck Surgery, Biomedical Research Institute, Pusan National University School of Medicine, Pusan National University Hospital, Busan, Republic of Korea.
- 신성찬교신저자Department of Otorhinolaryngology, Head and Neck Surgery, Biomedical Research Institute, Pusan National University School of Medicine, Pusan National University Hospital, Busan, Republic of Korea.
초록
Objective: This study aimed to evaluate the feasibility of the gasless transoral endoscopic thyroidectomy vestibular approach (TOETVA) using the Thyroidoscope, developed to maintain the surgical working space without CO2 insufflation. Materials and Methods: To prevent a potentially fatal CO2-related complication, we developed a retractable device, named the Thyroidoscope, which could maintain the surgical working space without CO2 insufflation. We conducted a preclinical cadaver study to evaluate its use in gasless TOETVA. Results: The Thyroidoscope provided a secure surgical field and stable image on the screen. We could successfully identify the recurrent laryngeal nerve, parathyroid gland, and other critical structures without inadvertent injury due to insertion of the Thyroidoscope. Conclusions: The Thyroidoscope provides sufficient working space to perform transoral thyroid surgery without the need for CO2 insufflation. Gasless TOETVA with the Thyroidoscope seems to be feasible and safe.
키워드
transoral thyroidectomytransoralthyroidminimally invasivecadaver studySUBCUTANEOUS EMPHYSEMA
식별자
- Scopus EID
- 2-s2.0-85068859280
- WoS UID
- 000465449800001



로그인
연구물 목록으로