Interlaminar Normal Stress Effects in Cylindrical Tubular Specimens of Graphite/Epoxy [±45]s Composites
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCI
- 저널
- Composites Research30(6) · pp.406 · 2017
- 피인용
- KCI 0
- ISSN
- 2288-2103
저자
- 안득만제1저자부산대학교
초록
The thin-walled cylindrical tubes are frequently used for the evaluation of fatigue property of composites. But the curvature of the tubular specimen induces interlaminar normal stress which may affect the fatigue property. In this paper interlaminar normal stress effect on the fatigue behaviour of thin-walled graphite/epoxy tubes [±45]s composites was studied experimentally. It was concluded that the interlaminar normal stress induced by the curvature of the cylinder has no discernible effect on the fatigue life. But excessive internal pressure can produce the stiffness increase and this affects the fatigue life of the cylindrical tubular composite.
키워드
FatigueGraphite/Epoxy CompositeInterlaminar Normal StressCylindrical Tubular Specimen
식별자
- KCI
- ART002302224



로그인