Development of a Novel Intraoperative Neuromonitoring System Using a Surface Pressure Sensor to Detect Muscle Movement: A Rabbit Model Study
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCISCIEScopus
- 저널 순위
- JCR Q3Scopus Q2
- 저널
- Clinical and Experimental Otorhinolaryngology12(2) · pp.217 · 2019
- 피인용
- Web of Science 7Scopus 8KCI 5
- FWCI (Scopus)
- 1.08
- JCR IF
- JCR 2018 1.55
- ISSN
- 1976-8710
저자
- 성의숙제1저자Department of Otolaryngology, Head and Neck Surgery and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University College of Medicine, Yangsan, Korea
- 이진춘Department of Otolaryngology, Head and Neck Surgery and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University College of Medicine, Yangsan, Korea
- 신성찬Department of Otolaryngology, Head and Neck Surgery and Medical Research Institute, Pusan National University College of Medicine, Busan, Korea
- 권현근Department of Otolaryngology, Head and Neck Surgery and Medical Research Institute, Pusan National University College of Medicine, Busan, Korea
- 김민식Department of Otolaryngology, Head and Neck Surgery and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University College of Medicine, Yangsan, Korea
- 김동조Department of Otolaryngology, Head and Neck Surgery and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University College of Medicine, Yangsan, Korea
- 노정훈Department of Biomedical Engineering, Pusan National University Hospital, Busan, Korea
- 이병주교신저자Department of Otolaryngology, Head and Neck Surgery and Medical Research Institute, Pusan National University College of Medicine, Busan, Korea
초록
Objectives. False-negative or false-positive responses in intraoperative neuromonitoring (IONM) using electromyography (EMG) in thyroid surgery pose a challenge. Therefore, we developed a novel IONM system that uses a surface pressure sensor instead of EMG to detect muscle twitching. This study aimed to investigate the feasibility and safety of a new IONM system using a piezo-electric surface pressure sensor in an experimental animal model. Methods. We developed the surface pressure sensor by modifying a commercial piezo-electric sensor. We evaluated the stimulus thresholds to detect muscle movement, as well as the amplitude and latency of the EMG and surface pressure sensor in six sciatic nerves of three rabbits, according to the stimulus intensity. Results. The surface pressure sensor detected the muscle movements in response to a 0.1 mA stimulation of all six sciatic nerves. There were no differences in the thresholds of stimulus intensity between the surface pressure sensor and EMC; recordings to detect muscle movements. Conclusion. It is possible to measure the change in surface pressure by using a piezo-electric surface pressure sensor instead of EMG to detect muscle movement induced by nerve stimulation.The application of IONM using a piezo-electric surface pressure sensor during surgery is noninvasive, safe, and feasible. Measuring muscle twitching to identify the state of the nerves using the novel IONM system can be an alternative to recording of EMG responses.
키워드
lntraoperative Neurophysiological MonitoringSurface Pressure SensorElectromyographyRecurrent Laryngeal NerveThyroidectomyRECURRENT LARYNGEAL NERVEENDOTRACHEAL-TUBETHYROID-SURGERYFACIAL-NERVEPARATHYROID SURGERYSTIMULATORPARALYSISINJURYPREVALENCE
식별자
- Scopus EID
- 2-s2.0-85065441843
- WoS UID
- 000462753000015
- KCI
- ART002470175



로그인
연구물 목록으로