A Low-Complexity I/Q Imbalance Calibration Method for Quadrature Modulator
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q1
- 저널
- IEEE TRANSACTIONS ON VERY LARGE SCALE INTEGRATION (VLSI) SYSTEMS27(4) · pp.974 · 2019
- 피인용
- Web of Science 18Scopus 22
- FWCI (Scopus)
- 0.46
- JCR IF
- JCR 2018 1.946
- ISSN
- 1063-8210
저자
- Kim, Jusung제1저자Department of Electronics and Controls Engineering, Hanbat National University, Daejeon, South Korea
- Jo, Han-ShinDepartment of Electronics and Controls Engineering, Hanbat National University, Daejeon, South Korea
- Lee, Kyoung-JaeDepartment of Electronics and Controls Engineering, Hanbat National University, Daejeon, South Korea
- Lee, Dong-HoDepartment of Information and Communication Engineering, Hanbat National University, Daejeon, South Korea
- Choi, Dae-HyunSchool of Electrical and Electronics Engineering, Chung-Ang University, Seoul, South Korea
- 김상길교신저자Department of Electronics Engineering, Pusan National University, Pusan, South Korea
초록
This brief presents a low-complexity I/Q (in-phase and quadrature components) imbalance calibration method for the transmitter using quadrature modulation. Impairments in analog quadrature modulator have a deleterious effect on the signal fidelity. Among the critical impairments, I/Q imbalance (gain and phase mismatches) deteriorates the residual sideband performance of the analog quadrature modulator degrading the error vector magnitude. Based on the theoretical mismatch analysis of the quadrature modulator, we propose a low-complexity I/Q imbalance extraction algorithm. After the parameter extraction, the transmitter is calibrated by imposing the counter imbalanced mismatch of the transmitter through the digital baseband. In comparison with existing I/Q imbalance calibration methods, the novelty of the proposed method lies in that: 1) only three spectrum measurements of the device-under-test are needed for extraction and calibration of gain and phase mismatches; 2) due to the blind nature of the calibration algorithm, the proposed approach can be readily applicable to an existing I/Q transmitter; 3) no extra hardware that degrades the calibration accuracy is required; and 4) due to the noniterative nature, the proposed method is faster and computationally more efficient than previously published methods.
키워드
Calibrationimage rejectionquadrature mismatchquadrature modulationresidual sideband (RSB)single sidebandtransmitterIQ IMBALANCECOMPENSATION
식별자
- Scopus EID
- 2-s2.0-85058900986
- WoS UID
- 000462444000022



로그인
연구물 목록으로