본문 바로가기

Ultra-Low-Dose Neck CT With Low-Dose Contrast Material for Preoperative Staging of Thyroid Cancer: Image Quality and Diagnostic Performance

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
저널
AMERICAN JOURNAL OF ROENTGENOLOGY212(4) · pp.748 · 2019
피인용
Web of Science 14Scopus 17
FWCI (Scopus)
1.2
JCR IF
JCR 2018 3.161
ISSN
0361-803X

저자

  1. 염정아제1저자Department of Radiology, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Yangsan Hospital, Yangsan, South Korea
  2. 노지은Department of Radiology, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Yangsan Hospital, Yangsan, South Korea
  3. 정연주Department of Radiology, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Hospital, Busan, South Korea
  4. 이진춘Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Yangsan Hospital, Yangsan, South Korea
  5. 김현열Department of Surgery, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Yangsan Hospital, Yangsan, South Korea
  6. Suh, Young JuDepartment of Biomedical Sciences, School of Medicine, Inha University, Incheon, South Korea
  7. 백승국교신저자Department of Radiology, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Yangsan Hospital, Yangsan, South Korea

초록

OBJECTIVE. Although CT has been used as a complementary diagnostic method for the preoperative diagnosis of thyroid cancer, it has the shortcomings of substantial radiation exposure and the use of contrast material (CM). The purpose of this article is to evaluate the image quality and diagnostic performance of 70-kVp thyroid CT with low volumes of CM versus conventional 120-kVp thyroid CT protocol. MATERIALS AND METHODS. Eighty patients referred for preoperative thyroid CT were randomly divided into two groups (group A: 40 patients, 70 kVp, 60 mL of CM; group B: 40 patients, 120 kVp, 100 mL of CM). Quantitative and qualitative image quality and radiation doses for the two groups were compared using the Mann-Whitney U and chi-square tests. Degrees of agreement between preoperative CT staging and pathologic results were evaluated and compared using the Wald statistic. RESULTS. Calculated signal-to-noise ratios of different anatomic structures, calculated contrast-to-noise ratios, overall image quality, subjective noise, and streak artifacts were not significantly different between the two groups (all p > 0.05), and neither were the accuracies of preoperative CT staging (all p > 0.05). The estimated effective doses were significantly lower in group A (mean [+/- SD], 0.52 +/- 0.14 mSv in group A and 2.28 +/- 0.29 mSv in group B; p < 0.001). CONCLUSION. Ultra-low-dose 70-kVp CT with a low volume of CM provides sufficient image quality for preoperative staging of thyroid cancer and substantially reduces the radiation dose compared with standard 120-kVp CT.

키워드

neckthyroid cancerultra-low-dose CTMODELED ITERATIVE RECONSTRUCTIONDUAL-ENERGY CTCOMPUTED-TOMOGRAPHYANGIOGRAPHYREDUCTIONIODINECARCINOMAHEADFEASIBILITYMETASTASIS

식별자

Scopus EID
2-s2.0-85063641024
WoS UID
000462026900014