본문 바로가기

Graphene-coated microballs for a hyper-sensitive vacuum sensor

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
SCIENTIFIC REPORTS9 · 2019
피인용
Web of Science 8Scopus 8
FWCI (Scopus)
0.26
JCR IF
JCR 2018 4.011
ISSN
2045-2322

저자

  1. 안성일제1저자교신저자Department of Chemistry Education, Pusan National University, Busan, South Korea
  2. Kim, Yong WooAdvanced Materials Engineering, Korea Polytechnic University, Jungwang dong, Shihung, South Korea
  3. Lee, Seong EuiAdvanced Materials Engineering, Korea Polytechnic University, Jungwang dong, Shihung, South Korea
  4. Kim, MinjunDepartment of Engineering in Energy and Applied Chemistry Silla University, Busan, South Korea
  5. Choi, Kyeong-KeunNational Institute for Nanomaterials Technology(NINT), Pohang University of Science and Technology(POSTECH), San 31, Hyoja-Dong, Nam-Gu, Pohang, South Korea
  6. Park, Jung-ChulDepartment of Engineering in Energy and Applied Chemistry Silla University, Busan, South Korea

초록

Reduced graphene oxide (RGO)-coated microballs of poly (methyl methacrylate) (PMMA) used for fabricating three-dimensional sensor (3D sensor), which are expected to exhibit high sensitivity compared with conventional two-dimensional (2D) sensors, were prepared using a reaction-based assembly process. The sheet resistance and transmittance of the RGO-coated balls decreased with increasing number of coatings, implying that the RGO was well adhered to the ball by the assembly method. Two types of vacuum pressure sensors using multiple balls and a single ball were fabricated using lift-off and air-blowing methods, respectively. At pressures < 1 torr, the sensors showed an increased resistance value due to the bending of graphene sheets by the Van der Waals attractive force. Further, the pressure versus resistance values at the logarithmic scale showed a linear relation, with a pressure reading error < 6%. Compared with the 2D sensor fabricated using RGO, the multiball sensor exhibited almost 4-5 times higher RRC value. The single-ball sensor showed reasonable reproducibility at various temperatures. Given the size and pressure reading range of the sensor, the sensitivity of the single-ball sensor at 100 degrees C was approximately 6,000 times greater than that of the sensor with the highest sensitivity reported in the literature. The increase in surface area and the geometric effect of the sensing part of the single-ball sensor appeared to be responsible for its abnormally high sensitivity.

키워드

COMPOSITES

식별자

Scopus EID
2-s2.0-85063332280
WoS UID
000461762600027