Dynamic Modeling and Robust Controllers Design for Doubly Fed Induction Generator-Based Wind Turbines under Unbalanced Grid Fault Conditions
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q3Scopus Q1
- 저널
- ENERGIES12(3) · 2019
- 피인용
- Web of Science 24Scopus 32
- FWCI (Scopus)
- 1.78
- JCR IF
- JCR 2018 2.707
- ISSN
- 1996-1073
저자
- 칸 임레인제1저자School of Electrical Engineering, Pusan National University, Busan, South Korea
- 젭 캄란School of Electrical Engineering, Pusan National University, Busan, South Korea
- 우딘 와카르School of Electrical Engineering, Pusan National University, Busan, South Korea
- 이슬람 사이프 울School of Electrical Engineering, Pusan National University, Busan, South Korea
- 이스파크 무함마드School of Electrical Engineering, Pusan National University, Busan, South Korea
- 후사인 사담School of Electrical Engineering, Pusan National University, Busan, South Korea
- 김희제교신저자School of Electrical Engineering, Pusan National University, Busan, South Korea
초록
High penetration of large capacity wind turbines into power grid has led to serious concern about its influence on the dynamic behaviors of the power system. Unbalanced grid voltage causing DC-voltage fluctuations and DC-link capacitor large harmonic current which results in degrading reliability and lifespan of capacitor used in voltage source converter. Furthermore, due to magnetic saturation in the generator and non-linear loads distorted active and reactive power delivered to the grid, violating grid code. This paper provides a detailed investigation of dynamic behavior and transient characteristics of Doubly Fed Induction Generator (DFIG) during grid faults and voltage sags. It also presents novel grid side controllers, Adaptive Proportional Integral Controller (API) and Proportional Resonant with Resonant Harmonic Compensator (PR+RHC) which eliminate the negative impact of unbalanced grid voltage on the DC-capacitor as well as achieving harmonic filtering by compensating harmonics which improve power quality. Proposed algorithm focuses on mitigation of harmonic currents and voltage fluctuation in DC-capacitor making capacitor more reliable under transient grid conditions as well as distorted active and reactive power delivered to the electric grid. MATLAB/Simulink simulation of 2 MW DFIG model with 1150 V DC-linked voltage has been considered for validating the effectiveness of proposed control algorithms. The proposed controllers performance authenticates robust, ripples free, and fault-tolerant capability. In addition, performance indices and Total Harmonic Distortions (THD) are also calculated to verify the robustness of the designed controller.
키워드
Wind Turbine (WT)Doubly Fed Induction Generator (DFIG)unbalanced grid voltageDC-linked voltage controlProportional Resonant with Resonant Harmonic Compensator (PR plus HC) controllerAdaptive Proportional Integral (API) controlpower controlPWM CONVERTERCONTROL STRATEGIESDFIGSYSTEMS