본문 바로가기

Diagnostic accuracy of F-18 FDG PET or PET/CT for detection of lymph node metastasis in clinically node negative head and neck cancer patients; A systematic review and meta-analysis

문서 유형
연구출판물 · 리뷰논문
등재
SCIEScopus
저널 순위
JCR Q4Scopus Q3
저널
AMERICAN JOURNAL OF OTOLARYNGOLOGY40(2) · pp.297 · 2019
피인용
Web of Science 46Scopus 58
FWCI (Scopus)
1.78
JCR IF
JCR 2018 0.932
ISSN
0196-0709

저자

  1. 김성장제1저자교신저자Department of Nuclear Medicine, Pusan National University Yangsan Hospital, Yangsan, South Korea
  2. 박경준Department of Nuclear Medicine, Pusan National University Hospital, Busan, South Korea
  3. 김근영Department of Nuclear Medicine, Pusan National University Hospital, Busan, South Korea

초록

Objective: The purpose of the current study was to investigate the diagnostic performance of F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) or positron emission tomography/computed tomography (PET/CT) for the detection of cervical lymph node (LN) metastasis in clinically node negative head and neck squamous cell cancer (cNO HNSCC) patients through a systematic review and meta-analysis. Methods: The PubMed and EMBASE database, from the earliest available date of indexing through April 30, 2018, were searched for studies evaluating the diagnostic performance of F-18 FDG PET or PET/CT for the detection of LN metastasis in cNO HNSCC patients. We determined the sensitivities and specificities across studies, calculated positive and negative likelihood ratios (LR+ and LR), and constructed summary receiver operating characteristic (SROC) curves. Results: Across 18 studies (1044 patients), the pooled sensitivity for F-18 FDG PET or PET/CT for the detection of LN metastasis was 0.58 and a pooled specificity of 0.87 for patient based analysis. Neck side based analysis showed the pooled sensitivity of 0.67 and a pooled specificity of 0.85. Level based study demonstrated the pooled sensitivity of 0.53 and a pooled specificity of 0.97 (95% CI; 0.95-0.98). In meta-regression analysis, no definite variable was the source of the study heterogeneity. Conclusion: The current meta-analysis showed the low sensitivity and moderate specificity of F-18 FDG PET/CT for the detection of cervical LN metastasis in cNO HNSCC patients. Level based analysis of F-18 FDG PET or PET/CT has a high specificity and NPV for the detection of cervical metastatic LN detection.

키워드

F-18 FDGPETPET/CT: Head and neck cancerLymph nodeSQUAMOUS-CELL CARCINOMAPOSITRON-EMISSION-TOMOGRAPHYFINE-NEEDLE-ASPIRATIONORAL-CAVITYCOMPUTED-TOMOGRAPHYN0DISSECTIONULTRASOUNDCT/MRIBIOPSY

식별자

Scopus EID
2-s2.0-85056882908
WoS UID
000460493900034