본문 바로가기

Comparative analysis of large macular hole surgery using an internal limiting membrane insertion versus inverted flap technique

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
BRITISH JOURNAL OF OPHTHALMOLOGY103(2) · pp.245 · 2019
피인용
Web of Science 78Scopus 93
FWCI (Scopus)
5.97
JCR IF
JCR 2018 3.615
ISSN
0007-1161

저자

  1. 박종호제1저자Department of Ophthalmology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
  2. 이승민Department of Ophthalmology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
  3. 박성후Department of Ophthalmology, Medical Research Institute, Pusan National University Hospital, Busan, South Korea
  4. 이지은Department of Ophthalmology, Medical Research Institute, Pusan National University Hospital, Busan, South Korea
  5. 변익수교신저자Pusan National University School of Medicine, Yangsan, South Korea

초록

Background To determine whether the internal limiting membrane (ILM) insertion technique is as effective as the inverted ILM flap technique for the initial surgical treatment of eyes with large idiopathic macular holes (MHs). Methods This retrospective, non-randomised, comparative clinical study included 41 eyes with large MHs (minimum diameter >500 mu m) that were treated using the ILM insertion technique or the inverted ILM flap technique. The hole closure rate, postoperative best corrected visual acuity (BCVA) and swept source optical coherence tomography findings were analysed at 6 months after surgery. Results There were 15 and 26 eyes in the insertion and inverted flap groups, respectively. Hole closure was achieved in all eyes. The mean final BCVA was better in the inverted flap group than in the insertion group (0.527 vs 0.773, p=0.006), although significant postoperative improvements were observed in both groups (p<0.001). Postoperative foveal discolouration was more common in the insertion group than in the inverted flap group (86.7% vs 7.7%, p<0.001). Complete resolution of ellipsoid zone and external limiting membrane defects was observed in 7 and 18 eyes, respectively, in the inverted flap group; in contrast, complete resolution was not observed in any of the eyes in the insertion group (p=0.035 and p<0.001, respectively). Conclusion The ILM insertion technique may be as effective as the inverted ILM flap technique for the closure of large MHs. However, the latter technique results in better recovery of photoreceptor layers and, consequently, better postoperative visual acuity.

키워드

internal limiting membraneinverted flaplarge macular holeoptical coherence tomographyvisual acuityINDOCYANINE GREENTRANSPLANTATIONMANAGEMENTEFFICACYMULLER

식별자

Scopus EID
2-s2.0-85054403486
WoS UID
000459028400016