본문 바로가기

Design of microfluidic viscometer based on pressure estimation

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q4Scopus Q3
저널
JOURNAL OF VISUALIZATION22(1) · pp.25 · 2019
피인용
Web of Science 11Scopus 10
FWCI (Scopus)
0.44
JCR IF
JCR 2018 0.879
ISSN
1343-8875

저자

  1. 강동국제1저자School of Mechanical Engineering, Pusan National University, Busan, South Korea
  2. 송재민Department of Oral and Maxillofacial Surgery, School of Dentistry, Pusan National University, Busan, South Korea
  3. 염은섭교신저자School of Mechanical Engineering, Pusan National University, Busan, South Korea

초록

Accurate measurement of viscosity using small samples is important considering the role of viscosity in the dynamics of physical, chemical, and biological systems. The microfluidic viscometer proposed in previous studies can measure the viscosity of fluids by estimating the pressure between samples and reference flows from the interfacial width. Therefore, accurate detection of the interfacial width is important in terms of the performance of a viscometer. We investigate flow behaviors in the microfluidic viscometer depending on their shape. In the simulation results, sample and reference flows are accelerated around the sharp corners of the viscometer. Flow disturbance around corners results in regions with a high-shear rate. The area of the high-shear region becomes wider as the confluence angle increases. To experimentally check the variation of flow conditions depending on the confluence angle, the flow rate and interfacial width were measured in a microfluidic viscometer designed using mold fabricated with a 3D printer. The width ratios obtained from the experiment results are varied depending on the confluence angle of the viscometer. This indicates that a high-shear region around a sharp corner can lead to inaccurate measurement of the microfluidic viscometer. To reduce the high-shear regions, the distributions of the shear rate were investigated depending on the degree of the rounded corners. A region with a high-shear rate is significantly decreased by increasing the radius of curvature. From the results, a microfluidic viscometer with a confluence angle of 30 degrees and rounded curves is suitable for measuring the viscosity based on an estimation of the pressure. By using the selected design of the microfluidic viscometer, the viscosity of a blood sample is reasonably measured depending on the shear rate. A microfluidic viscometer with a suitable design can be utilized as a viscometer with significant advantages in terms of mobility and ease of operation by combining it with mobile sensing equipment.

키워드

ViscosityMicrofluidic viscometerPressure estimationNumerical simulation

식별자

Scopus EID
2-s2.0-85055722885
WoS UID
000458456800003