Differentiation Between Normal and Cancerous Human Urothelial Cell Lines Using Micro-Electrical Impedance Spectroscopy at Multiple Frequencies

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q4Scopus Q3
피인용
Web of Science 5Scopus 5
FWCI (Scopus)
0.07
JCR IF
JCR 2018 1.306
ISSN
1609-0985

저자

  1. 김현우제1저자Department of Urology, Pusan National University Hospital, Busan, South Korea
  2. Park, YangkyuSchool of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju, South Korea
  3. Yun, JohoDepartment of Biomedical Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju, South Korea
  4. Lim, JuhunDepartment of Biomedical Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju, South Korea
  5. 이정주Department of Urology, Pusan National University Hospital, Busan, South Korea
  6. 신동길교신저자Department of Urology, Pusan National University Hospital, Busan, South Korea
  7. Lee, Jong-HyunSchool of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju, South Korea

초록

The present study aims to investigate differences in impedance between normal (SV-HUC-1) and cancerous (TCCSUP) human urothelial cell lines at multiple frequencies by using a micro-electrical impedance spectroscopy (mu EIS) device. A mu EIS device was designed to measure the impedance of SV-HUC-1 and TCCSUP cells as the cells passed the sensing electrodes in the microfluidic channel. The cellular impedance was measured at frequencies of 10, 50, 100, 500kHz, and 1MHz, and the impedance values were compared at each frequency to investigate differences between the two cell lines. Additionally, the linear correlation between impedance and frequency was analyzed. The number of SV-HUC-1 and TCCSUP cells measured was 13 and 9, 21 and 10, 16 and 24, 8 and 8, and 11 and 22 cells at the frequencies of 10, 50, 100, 500kHz, and 1MHz, respectively. TCCSUP had significantly smaller amplitudes than SV-HUC-1 at 10, 50, and 100kHz (p=0.030, p=0.031, and p<0.001, respectively). Moreover, significant differences in phase angle were observed between cell lines at 100, 500kHz, and 1MHz (p<0.001 in all). A significant difference between cell lines in terms of amplitude and phase angle was observed concurrently at 100kHz. The amplitude of both the cell lines was negatively correlated to frequency, while the phase angle presented no correlation. In conclusion, the mu EIS device could effectively differentiate between SV-HUC-1 and TCCSUP on the basis of their impedance.

키워드

Diagnostic equipmentLab-on-a-chip devicesElectrodesEngineeringTechnologyImpedanceBLADDER-CANCERMICROFLUIDIC DEVICECYTOPLASM CONDUCTIVITYDIELECTRIC-PROPERTIESMEMBRANE CAPACITANCEDIAGNOSTIC-ACCURACYURINARY CYTOLOGYBIOIMPEDANCEMETAANALYSISTISSUES