Difference assessment of composite resins and sound tooth applicable in the resin-imbedded tooth for resin repair using fluorescence, microhardness, DIAGNOdent, and X-ray image
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- CLINICAL ORAL INVESTIGATIONS23(1) · pp.293 · 2019
- 피인용
- Web of Science 3Scopus 5
- FWCI (Scopus)
- 0.41
- JCR IF
- JCR 2018 2.453
- ISSN
- 1432-6981
저자
- 정태성제1저자Department of Pediatric Dentistry, School of Dentistry, Pusan National University, Yangsan, South Korea
- 박정길Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, South Korea
- Ko, Ching-ChangDepartment of Orthodontics, School of Dentistry, University of North Carolina, Chapel Hill, United States
- Garcia-Godoy, FranklinDepartment of Bioscience Research, University of Tennessee Health Science Center, College of Dentistry, Memphis, United States
- 권용훈교신저자Department of Dental Materials, School of Dentistry, Pusan National University, Yangsan, South Korea
초록
ObjectiveVisual differentiation of resin and tooth in a tooth cavity is not simple due to their highly similar shade. The purpose of the present study was to find any noninvasive method which can effectively differentiate resin from sound tooth in a resin-imbedded tooth for resin repair.Materials and methodsFor the study, various resin products were imbedded into the cavity of sound tooth. By applying laser of different wavelengths, autofluorescence (AF) of sound tooth and resin products were obtained. Microhardness, X-ray radiograph, and DIAGNOdent were tested for each tooth, resin product, and resin-imbedded tooth.ResultsFor the AF spectra obtained using the 405-nm wavelength, sound tooth has emission peak at 440-470nm and near 490nm. Sound tooth has several times higher microhardness than resin products regardless of position in tooth subsurface. Due to the difference of radiopaque fillers' composition and concentration, resin products have different brightness in the X-ray radiograph. DIAGNOdent readings for tooth and resin products were inconsistently different, and the difference of obtained values was slightly not to be applicable for the differentiation.ConclusionAmong the tested methods, with noninvasive treatment, AF spectrum by the 405-nm wavelength showed the apparent difference between resin and tooth.Clinical significanceFor the resin repair in a resin-imbedded tooth cavity, AF spectrum produced by 405-nm wavelength could be a useful method in tracing the resin-tooth boundary if combined with conventional X-ray radiography.
키워드
Composite resinToothFluorescenceMicrohardnessDIAGNOdentX-ray imageLASER FLUORESCENCERADIOPACITYSPECTROSCOPYRESTORATIONS
식별자
- Scopus EID
- 2-s2.0-85045660485
- WoS UID
- 000455805600029



로그인
연구물 목록으로