본문 바로가기

The study on the power consumption for glass melting by cold crucible melter

문서 유형
연구출판물 · 학술지 논문
등재
KCISCIEScopus
피인용
Web of Science 0KCI 0
ISSN
1738-8228

저자

  1. 진현주제1저자부산대학교
  2. 이규호부산대학교
  3. 장영재글라스진택
  4. 배소영글라스진택
  5. 김태호부산대학교
  6. 정영준부산대학교
  7. 김영석부산대학교
  8. 이강택부산대학교
  9. 류봉기교신저자부산대학교

초록

Generally CCM (cold crucible melting) is not suitable for melting glass. However, in this study we described the quantitative relationship between the basic property of glass and power balance, the power absorption in the melt, the losses in the coil and the cold crucible, for melting glass in CCM. The dependence of power balance on the applied frequency and the electric conductivity has been found. Above 300 kHz, the glass (B) contained alkali ion which has the low resistance 3.0 Omega.cm at 900 degrees C and 1.36 Omega.cm at 1,100 degrees C was melted easily and 60% of the overall power was absorbed in the melt and 30% and 10% of the overall power was lost in the cold crucible and coil respectively. Under the same condition, the glass (A) contained non-alkali ion was not melted easily and 50% of the overall power was absorbed in the melt and 40% and 10% of the overall power was lost in the cold crucible and coil respectively. In conclusion, the small absorbed power of the overall power in melt prevented a successful melting as for glass A, and the successful melting depends on the relative size of the absorbed power in melt irrespective of the melting volume. Hence, as typical for direct induction heating method(CCM), the successful melting strongly depended on the chosen working frequency based on electric conductivity of glass, power balance and the control of the critical power which was absorbed in melt.

키워드

CCM(cold crucible melter)electric conductivitypower balance

식별자

WoS UID
000255190900003
KCI
ART001244635