Comparison of Color Light-Emitting Diode Corneal Topographer and Dual Rotating Scheimpflug-Placido Topographer

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q3Scopus Q2
저널
JOURNAL OF OPHTHALMOLOGY2018 · 2018
피인용
Web of Science 3Scopus 6
FWCI (Scopus)
0.73
JCR IF
JCR 2017 1.68
ISSN
2090-004X

저자

  1. Lee, Jae Hyuck제1저자Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, South Korea
  2. Lee, Yong WooDepartment of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, South Korea
  3. 이종수Department of Ophthalmology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Yangsan, South Korea
  4. Knorz, Michael C.Medical Faculty Mannheim of the University of Heidelberg, Mannheim, Germany
  5. Auffarth, Gerd U.International Vision Correction Research Centre (IVCRC), David J. Apple International Laboratory on Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
  6. Choi, Chul Young교신저자Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, South Korea

초록

Purpose. To compare measurements of anterior and posterior keratometric values, using a color light-emitting diode corneal topographer and a dual rotating Scheimpflug-Placido topographer. Methods. Anterior and posterior corneal index measurements were performed using a color light-emitting diode corneal topographer (Cassini) and a dual rotating Scheimpflug-Placido topographer (Galilei G4) and then compared. The paired t-test, intraclass correlation coefficients (ICCs), and Bland-Altman plots were used to evaluate the agreement between measurements. Results. Sixty postrefractive surgery eyes and 60 normal eyes were evaluated. Both the color light-emitting diode corneal topographer and the dual rotating Scheimpflug-Placido topographer provided highly repeatable corneal measurements (ICC > 0.969). The agreement levels between the 2 devices for anterior corneal power, astigmatism magnitude, and J0 and J45 values were ICC > 0.906 for the total group. However, the ICC values for posterior corneal power, astigmatism magnitude, and J0 and J45 values were lower than 0.681 for the total group. Conclusions. The anterior keratometric values obtained by the color light-emitting diode corneal topographer and the dual rotating Scheimpflug-Placido topographer showed high agreement levels, but the posterior keratometric values showed lower agreement levels.