본문 바로가기

Comparison of High Sensitivity and Conventional Flow Cytometry for Diagnosing Overt Paroxysmal Nocturnal Hemoglobinuria and Detecting Minor Paroxysmal Nocturnal Hemoglobinuria Clones

문서 유형
연구출판물 · 학술지 논문
등재
KCISCIEScopus
저널 순위
JCR Q2Scopus Q2
저널
Annals of Laboratory Medicine39(2) · pp.150 · 2019
피인용
Web of Science 2Scopus 1KCI 0
FWCI (Scopus)
0
JCR IF
JCR 2018 2.635
ISSN
2234-3806

저자

  1. Park, Sang Hyuk제1저자Department of Laboratory Medicine, University of Ulsan College of Medicine, Ulsan University Hospital, Ulsan, South Korea
  2. Jeong, JosephDepartment of Laboratory Medicine, University of Ulsan College of Medicine, Ulsan University Hospital, Ulsan, South Korea
  3. Lee, Seon-HoDepartment of Laboratory Medicine, University of Ulsan College of Medicine, Ulsan University Hospital, Ulsan, South Korea
  4. 유동원Department of Laboratory Medicine, Pusan National University Yangsan Hospital, Yangsan, South Korea
  5. Choi, YunsukDepartment of Hematology and Cellular Therapy, University of Ulsan College of Medicine, Ulsan University Hospital, Ulsan, South Korea
  6. Jo, Jae-CheolDepartment of Hematology and Cellular Therapy, University of Ulsan College of Medicine, Ulsan University Hospital, Ulsan, South Korea
  7. Lim, Ji-Hun교신저자Department of Laboratory Medicine, University of Ulsan College of Medicine, Ulsan University Hospital, Ulsan, South Korea

초록

Background: High sensitivity flow cytometry (HS-FCM) was recently developed for diagnosing paroxysmal nocturnal hemoglobinuria (PNH). We compared its performance with conventional flow cytometry (C-FCM) for diagnosing overt PNH and detecting minor (0.1-1%) PNH clones in aplastic anemia (AA)/low-grade myelodysplastic syndrome (MDS) patients. Methods: C-FCM and HS-FCM were performed simultaneously on 41 samples from healthy controls and 23 peripheral blood samples from 15 AA/low-grade MDS and eight PNH patients, using a Navios flow cytometer (Beckman Coulter, Miami, FL, USA). Results were compared. Results: No healthy control samples had PNH clone size >0.01%. For granulocytes, C-FCM detected a smaller PNH clone size than HS-FCM (mean difference: 0.7-1.7%). In AA/low-grade MDS patients, three samples showed >1% PNH clones with C-FCM but not with HS-FCM. Seven samples showed minor PNH clones by C-FCM, but HS-FCM showed negative results for all these samples. In PNH patients, C-FCM detected a smaller PNH clone size than HS-FCM (mean difference: 1.9-5.0%). For red blood cells, C-FCM detected a greater PNH clone size than HS-FCM (mean difference: 1.5%). In AA/low-grade MDS patients, C-FCM showed >1% PNH clones in six samples, but HS-FCM showed >1% PNH clones in none of the samples. C-FCM detected minor PNH clones in nine samples, but six of them were negative by HS-FCM. In PNH patients, C-FCM detected a greater PNH clone size than HS-FCM (mean difference: 2.5%). Conclusions: HS-FCM can sensitively detect minor PNH clones and reduce false-positive C-FCM minor PNH clone cases in AA/low-grade MDS patients.

식별자

Scopus EID
2-s2.0-85056627397
WoS UID
000455501200005
KCI
ART002437477