Comparison of High Sensitivity and Conventional Flow Cytometry for Diagnosing Overt Paroxysmal Nocturnal Hemoglobinuria and Detecting Minor Paroxysmal Nocturnal Hemoglobinuria Clones
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCISCIEScopus
- 저널 순위
- JCR Q2Scopus Q2
- 저널
- Annals of Laboratory Medicine39(2) · pp.150 · 2019
- 피인용
- Web of Science 2Scopus 1KCI 0
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2018 2.635
- ISSN
- 2234-3806
저자
- Park, Sang Hyuk제1저자Department of Laboratory Medicine, University of Ulsan College of Medicine, Ulsan University Hospital, Ulsan, South Korea
- Jeong, JosephDepartment of Laboratory Medicine, University of Ulsan College of Medicine, Ulsan University Hospital, Ulsan, South Korea
- Lee, Seon-HoDepartment of Laboratory Medicine, University of Ulsan College of Medicine, Ulsan University Hospital, Ulsan, South Korea
- 유동원Department of Laboratory Medicine, Pusan National University Yangsan Hospital, Yangsan, South Korea
- Choi, YunsukDepartment of Hematology and Cellular Therapy, University of Ulsan College of Medicine, Ulsan University Hospital, Ulsan, South Korea
- Jo, Jae-CheolDepartment of Hematology and Cellular Therapy, University of Ulsan College of Medicine, Ulsan University Hospital, Ulsan, South Korea
- Lim, Ji-Hun교신저자Department of Laboratory Medicine, University of Ulsan College of Medicine, Ulsan University Hospital, Ulsan, South Korea
초록
Background: High sensitivity flow cytometry (HS-FCM) was recently developed for diagnosing paroxysmal nocturnal hemoglobinuria (PNH). We compared its performance with conventional flow cytometry (C-FCM) for diagnosing overt PNH and detecting minor (0.1-1%) PNH clones in aplastic anemia (AA)/low-grade myelodysplastic syndrome (MDS) patients. Methods: C-FCM and HS-FCM were performed simultaneously on 41 samples from healthy controls and 23 peripheral blood samples from 15 AA/low-grade MDS and eight PNH patients, using a Navios flow cytometer (Beckman Coulter, Miami, FL, USA). Results were compared. Results: No healthy control samples had PNH clone size >0.01%. For granulocytes, C-FCM detected a smaller PNH clone size than HS-FCM (mean difference: 0.7-1.7%). In AA/low-grade MDS patients, three samples showed >1% PNH clones with C-FCM but not with HS-FCM. Seven samples showed minor PNH clones by C-FCM, but HS-FCM showed negative results for all these samples. In PNH patients, C-FCM detected a smaller PNH clone size than HS-FCM (mean difference: 1.9-5.0%). For red blood cells, C-FCM detected a greater PNH clone size than HS-FCM (mean difference: 1.5%). In AA/low-grade MDS patients, C-FCM showed >1% PNH clones in six samples, but HS-FCM showed >1% PNH clones in none of the samples. C-FCM detected minor PNH clones in nine samples, but six of them were negative by HS-FCM. In PNH patients, C-FCM detected a greater PNH clone size than HS-FCM (mean difference: 2.5%). Conclusions: HS-FCM can sensitively detect minor PNH clones and reduce false-positive C-FCM minor PNH clone cases in AA/low-grade MDS patients.
식별자
- Scopus EID
- 2-s2.0-85056627397
- WoS UID
- 000455501200005
- KCI
- ART002437477



로그인
연구물 목록으로