Devising negative pressure within intercuff space reduces microaspiration

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q3Scopus Q2
저널
BMC ANESTHESIOLOGY18 · 2018
피인용
Web of Science 2Scopus 2
FWCI (Scopus)
0.23
JCR IF
JCR 2017 1.788
ISSN
1471-2253

저자

  1. Sohn, H. M.제1저자Department of Anesthesiology and Pain Medicine, Seoul National University, Bundang Hospital, Gyeonggi-do, South Korea
  2. 백지석Department of Anesthesiology and Pain Medicine, Pusan National University Hospital, Busan, South Korea
  3. Hwang, J. Y.Department of Anesthesiology and Pain Medicine, SMG-SNU Boramae Medical Center, Seoul, South Korea
  4. Kim, S. Y.Department of Anesthesiology and Pain Medicine, Seoul National University, Bundang Hospital, Gyeonggi-do, South Korea
  5. Han, S. H.Department of Anesthesiology and Pain Medicine, Seoul National University, Bundang Hospital, Gyeonggi-do, South Korea
  6. Kim, J. H.교신저자Department of Anesthesiology and Pain Medicine, Seoul National University, Bundang Hospital, Gyeonggi-do, South Korea

초록

BackgroundMicroaspiration past the tracheal tube cuffs causes ventilator-associated pneumonia. The objective of the current study was to evaluate whether creating negative pressure between the tracheal double cuffs could block the fluid passage past the tracheal tube cuffs.MethodsA new negative pressure system was devised between the double cuffs through a suction hole in the intercuff space. Blue-dyed water was instilled above the cuff at negative suction pressures of -54, -68, -82, -95, -109, -122, and-136 cmH(2)O, and the volume leaked was measured in an underlying water trap after 10min. Leakage tests were also performed during positive pressure ventilation, and using higher-viscosity materials. The actual negative pressures delivered at the hole of double cuffs were obtained by placing microcatheter tip between the intercuff space and the artificial trachea.ResultsNo leakage occurred past the double cuff at -136 cmH(2)O suction pressure at all tracheal tube cuff pressures. The volume leaked decreased significantly as suction pressure increased. When connected to a mechanical ventilator, no leakage was found at -54 cmH(2)suction pressure. Volume of the higher-viscosity materials (dynamic viscosity of 63-108cP <cP> and 370-430cP) leaked was small compared to that of normal saline (0.9-1.1cP). The pressures measured in the intercuff space corresponded to 3.8-5.9% of those applied.ConclusionsA new prototype double cuff with negative pressure in the intercuff space completely prevented water leakage. The negative pressure transmitted to the tracheal inner wall was a small percentage of that applied.

키워드

Artificial tracheaAspirationDouble cuffsEndotracheal tubeNegative pressureVENTILATOR-ASSOCIATED PNEUMONIATRACHEAL TUBE CUFFCONTINUOUS ASPIRATIONSUBGLOTTIC SECRETIONFLUID LEAKAGE