본문 바로가기

Early Detection of Hemodynamic Responses Using EEG: A Hybrid EEG-fNIRS Study

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
피인용
Web of Science 60Scopus 72
FWCI (Scopus)
3.96
JCR IF
JCR 2017 2.871
ISSN
1662-5161

저자

  1. 칸 무하마드 자와드제1저자School of Mechanical Engineering, Pusan National University, Busan, South Korea
  2. 어스만 가풀School of Mechanical Engineering, Pusan National University, Busan, South Korea
  3. 홍금식교신저자School of Mechanical Engineering, Pusan National University, Busan, South Korea

초록

Enhanced classification accuracy and a sufficient number of commands are highly demanding in brain computer interfaces (BCIs). For a successful BCI, early detection of brain commands in time is essential. In this paper, we propose a novel classifier using a modified vector phase diagram and the power of electroencephalography (EEG) signal for early prediction of hemodynamic responses. EEG and functional near-infrared spectroscopy (fNIRS) signals for a motor task (thumb tapping) were obtained concurrently. Upon the resting state threshold circle in the vector phase diagram that uses the maximum values of oxy- and deoxy-hemoglobin (Delta HbO and Delta HbR) during the resting state, we introduce a secondary (inner) threshold circle using the Delta HbO and Delta HbR magnitudes during the time window of 1 s where an EEG activity is noticeable. If the trajectory of Delta HbO and Delta HbR touches the resting state threshold circle after passing through the inner circle, this indicates that Delta HbO was increasing and Delta HbR was decreasing (i.e., the start of a hemodynamic response). It takes about 0.5 s for an fNIRS signal to cross the resting state threshold circle after crossing the EEG-based circle. Thus, an fNIRS-based BCI command can be generated in 1.5 s. We achieved an improved accuracy of 86.0% using the proposed method in comparison with the 63.8% accuracy obtained using linear discriminant analysis in a window of 0 similar to 1.5 s. Moreover, the active brain locations (identified using the proposed scheme) were spatially specific when a t-map was made after 10 s of stimulation. These results demonstrate the possibility of enhancing the classification accuracy for a brain-computer interface with a time window of 1.5 s using the proposed method.

키워드

brain-computer interface (BCI)functional near-infrared spectroscopy (fNIRS)electroencephalography (EEG)hybrid EEG-fNIRShemodynamic responsevector phase diagramclassifierBRAIN-COMPUTER-INTERFACEINITIAL DIPSBCIMOTORCORTEXCLASSIFICATIONSIGNALSNIRSPERFORMANCEEXTRACTION

식별자

Scopus EID
2-s2.0-85059025370
WoS UID
000451687700001