본문 바로가기

Sub-millisievert CT colonography: effect of knowledge-based iterative reconstruction on the detection of colonic polyps

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
EUROPEAN RADIOLOGY28(12) · pp.5258 · 2018
피인용
Web of Science 11Scopus 13
FWCI (Scopus)
0.66
JCR IF
JCR 2017 4.027
ISSN
0938-7994

저자

  1. Kang, Hyo-Jin제1저자Department of Radiology, Seoul National University Hospital, Seoul, South Korea
  2. Kim, Se Hyung교신저자Department of Radiology, Seoul National University Hospital, Seoul, South Korea
  3. Shin, Cheong-IlDepartment of Radiology, Seoul National University Hospital, Seoul, South Korea
  4. Joo, IjinDepartment of Radiology, Seoul National University Hospital, Seoul, South Korea
  5. 류화성Pusan National University Yangsan Hospital, Yangsan, South Korea
  6. Kim, Sang GyunDepartment of Internal medicine, Seoul National University Hospital, Seoul, South Korea
  7. Im, Jong PilDepartment of Internal medicine, Seoul National University Hospital, Seoul, South Korea
  8. Han, Joon KooDepartment of Radiology, Seoul National University Hospital, Seoul, South Korea

초록

ObjectivesTo assess the feasibility of ultra-low dose computed tomography colonography (CTC) using knowledge-based iterative reconstruction (IR) and to determine its effect on polyp detection.MethodsForty-nine prospectively-enrolled patients underwent ultra-low dose CTC in the supine (100 kVp/20 mAs) and prone positions (80 kVp/20 mAs), followed by same-day colonoscopy. Thereafter, images were reconstructed using filtered back projection (FBP) and knowledge-based IR (IMR; Philips Healthcare, Best, Netherlands) algorithms. Effective radiation dose of CTC was recorded. Pooled per-polyp sensitivity and positive predictive value of three radiologists was analysed and compared between FBP and IMR. Image quality was assessed on a five-point scale and image noise was recorded using standard deviations.ResultsMean effective radiation dose of ultra-low dose CTC was 0.90 0.06 mSv. Eighty-nine polyps were detected on colonoscopy (mean, 8.5 4.7 mm). The pooled per-polyp sensitivity for polyps 6.0-9.9 mm (n = 22) on CTC reconstructed with IMR (36/66, 54.5%) was not significantly different with that using FBP algorithm (34/66, 51.5%) (p = 0.414). For polyps 10 mm (n = 35), however, the pooled per-polyp sensitivity on CTC with IMR (73/105, 69.5%) was significantly higher than that with FBP (55/105, 52.4%) (p < 0.001). In particular, the difference of per-polyp sensitivity was statistically significant in intermediate (p = 0.014) and novice (p = 0.003) reviewers. Furthermore, mean image noise of IMR (8.4 6.2 HU) was significantly lower than that of FBP (37.5 13.9 HU) (p < 0.001) and image quality with IMR was significantly better than with FBP in all evaluated segments in all reviewers (all ps < 0.001).ConclusionsSub-mSv CTC reconstructed with IMR was feasible for the detection of clinically significant polyps, demonstrating 70% per-polyp sensitivity of polyps 10 mm, while allowing significant noise reduction and improvement in image quality compared with FBP reconstruction.

키워드

Colonographycomputed tomographicImage reconstructionColonic polypFeasibility studiesSensitivityCONTRAST BARIUM ENEMAIMAGE QUALITYCOLORECTAL-CANCERDOSE REDUCTIONPERFORMANCECOLONOSCOPYCONSPICUOUSNESSRADIOLOGISTSALGORITHMSRESOLUTION

식별자

Scopus EID
2-s2.0-85048281948
WoS UID
000451353500038