본문 바로가기

Optimal Generation of Ten Individual Green-to-Red Raman Source for Wavelength-Dependent Real-Time OR-PAM Images

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
피인용
Web of Science 12Scopus 13
FWCI (Scopus)
0.79
JCR IF
JCR 2018 4.681
ISSN
1077-260X

저자

  1. 조순우제1저자Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
  2. Kang, HeesungCenter for Nano-Bio Measurement, Korea Research Institute of Standards and Science, Daejeon, South Korea
  3. 박상민Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
  4. 임국빈Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
  5. 박충열Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
  6. Lee, Sang-WonCenter for Nano-Bio Measurement, Korea Research Institute of Standards and Science, Daejeon, South Korea
  7. 김창석교신저자Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
  8. Lee, Tae GeolCenter for Nano-Bio Measurement, Korea Research Institute of Standards and Science, Daejeon, South Korea

초록

In this study, ten individual green-to-red stimulated Raman scattering (SRS) peaks are optimally generated for wavelength-dependent real-time optical-resolution photoacoustic microscopy (OR-PAM) with contrast agents. Exogenous contrast agents, such as dyes, semiconducting polymers, and metallic nanoparticles, are frequently used in OR-PAM to provide structural, functional, and molecular images of biological samples with a high spatial resolution. For an effective use of various exogenous contrast agents for functional or molecular OR-PAM, selectable visible and near-infrared wavelengths are needed to select the absorption wavelengths of the contrast agents. Therefore, we optimized an SRS source, which can selectively generate ten narrowband SRS peaks with a bandwidth smaller than 11 nm and individually produce sufficient threshold pulse energies (116-756 nJ) at a high pulse repetition rate (PRR) of 300 kHz. The wavelength-dependent photoacoustic signal was easily obtained in a methylene blue phantom and in vivo mouse studies using the optimal generation conditions of the ten-wavelength green-to-red SRS source, from 545 to 695 nm. In particular, for the first time, wavelength-dependent real-time in vivo OR-PAM images at a PRR of hundreds of kilohertz were obtained to distinguish gold nanoparticles from distributed blood vessels of a mouse ear.

키워드

Fast lightlight sourcesmultispectral imagingphotoacoustic imagingRaman scatteringRESOLUTION PHOTOACOUSTIC MICROSCOPYGOLD NANOPARTICLESFIBER-LASERSCATTERING

식별자

Scopus EID
2-s2.0-85053299904
WoS UID
000448640200001