Optimal Generation of Ten Individual Green-to-Red Raman Source for Wavelength-Dependent Real-Time OR-PAM Images
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS25(1) · 2019
- 피인용
- Web of Science 12Scopus 13
- FWCI (Scopus)
- 0.79
- JCR IF
- JCR 2018 4.681
- ISSN
- 1077-260X
저자
- 조순우제1저자Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
- Kang, HeesungCenter for Nano-Bio Measurement, Korea Research Institute of Standards and Science, Daejeon, South Korea
- 박상민Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
- 임국빈Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
- 박충열Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
- Lee, Sang-WonCenter for Nano-Bio Measurement, Korea Research Institute of Standards and Science, Daejeon, South Korea
- 김창석교신저자Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
- Lee, Tae GeolCenter for Nano-Bio Measurement, Korea Research Institute of Standards and Science, Daejeon, South Korea
초록
In this study, ten individual green-to-red stimulated Raman scattering (SRS) peaks are optimally generated for wavelength-dependent real-time optical-resolution photoacoustic microscopy (OR-PAM) with contrast agents. Exogenous contrast agents, such as dyes, semiconducting polymers, and metallic nanoparticles, are frequently used in OR-PAM to provide structural, functional, and molecular images of biological samples with a high spatial resolution. For an effective use of various exogenous contrast agents for functional or molecular OR-PAM, selectable visible and near-infrared wavelengths are needed to select the absorption wavelengths of the contrast agents. Therefore, we optimized an SRS source, which can selectively generate ten narrowband SRS peaks with a bandwidth smaller than 11 nm and individually produce sufficient threshold pulse energies (116-756 nJ) at a high pulse repetition rate (PRR) of 300 kHz. The wavelength-dependent photoacoustic signal was easily obtained in a methylene blue phantom and in vivo mouse studies using the optimal generation conditions of the ten-wavelength green-to-red SRS source, from 545 to 695 nm. In particular, for the first time, wavelength-dependent real-time in vivo OR-PAM images at a PRR of hundreds of kilohertz were obtained to distinguish gold nanoparticles from distributed blood vessels of a mouse ear.
키워드
Fast lightlight sourcesmultispectral imagingphotoacoustic imagingRaman scatteringRESOLUTION PHOTOACOUSTIC MICROSCOPYGOLD NANOPARTICLESFIBER-LASERSCATTERING
식별자
- Scopus EID
- 2-s2.0-85053299904
- WoS UID
- 000448640200001



로그인