본문 바로가기

Optimizing the cutoff for the identification of skin sensitizers by the HaCaSens assay: Introducing an ROC-analysis-based cutoff approach

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
저널
TOXICOLOGY LETTERS299 · pp.86 · 2018
피인용
Web of Science 2Scopus 2
FWCI (Scopus)
0.08
JCR IF
JCR 2017 3.166
ISSN
0378-4274

저자

  1. Chung, Hyewon제1저자Department of Microbiology and Immunology, Institute of Endemic Disease, College of Medicine, Seoul National University, Seoul, South Korea
  2. 김은주College of Pharmacy, Pusan National University, Busan, South Korea
  3. Quan, HailianDepartment of Microbiology and Immunology, Institute of Endemic Disease, College of Medicine, Seoul National University, Seoul, South Korea
  4. Jung, DaunDepartment of Microbiology and Immunology, Institute of Endemic Disease, College of Medicine, Seoul National University, Seoul, South Korea
  5. Gautam, RaviDepartment of Occupational Health, College of Bio-Medical Sciences, Daegu Catholic University, Daegu, South Korea
  6. Cho, AhrangDepartment of Occupational Health, College of Bio-Medical Sciences, Daegu Catholic University, Daegu, South Korea
  7. Kim, Chang YulDepartment of Occupational Health, College of Bio-Medical Sciences, Daegu Catholic University, Daegu, South Korea
  8. Kang, MiJeongCollege of Pharmacy, Yeungnam University, Gyeongsan, South Korea
  9. Che, Jeong-HwanBiomedical Center for Animal Resource Development, Seoul National University College of Medicine, Seoul, South Korea
  10. Lee, Eung-SeokCollege of Pharmacy, Yeungnam University, Gyeongsan, South Korea
  11. Jeong, Tae CheonCollege of Pharmacy, Yeungnam University, Gyeongsan, South Korea
  12. Heo, Yong교신저자Department of Occupational Health, College of Bio-Medical Sciences, Daegu Catholic University, Daegu, South Korea
  13. Seok, Seung HyeokDepartment of Microbiology and Immunology, Institute of Endemic Disease, College of Medicine, Seoul National University, Seoul, South Korea

초록

The worldwide restricted use of animal testing makes it challenging to identify the skin sensitizing potentials of newly manufactured products. The HaCaSens assay has shown promise as an in vitro skin sensitizing assay comparable to existing assays, and is currently under pre-validation. However, there is little agreement on how to assess the results of the assay to discriminate sensitizers from non-sensitizers as the stimulation index (SI) cutoff value was arbitrarily chosen without appropriate statistical methods. Here, we investigated the SI cutoff values in identifying sensitizers to obtain the optimal value. Sensitivities and specificities were calculated for a set of 30 test substances, and plotted in receiver operator characteristics (ROC) curves. The SI cutoff values with the highest sum of sensitivity and specificity according to LLNA data were 2.2, 1.8 and 3.0 for interleukin 1 alpha (IL-1 alpha), interleukin 6 (IL-6), and the combination of the two cytokines respectively. Also, the same statistical analysis of human data demonstrated optimal SI cutoff values 2.0, 2.0 and 3.2 for the same respective parameters. When considering the predictive capacity of each possible SI cutoff value determined by ROC curves, the optimal value for HaCaSens is 3.0 for the combination of IL-1 alpha and IL-6 as it had the highest sensitivity (90.9%), specificity (75.0%) and accuracy (86.7%) based on LLNA data. Thus, we recommend the wide use of the SI cutoff value of 3.0 to ensure consistent endpoints.

키워드

HaCaSensSkin sensitizationInterleukin-1 alphaInterleukin-6CutoffROC analysisLINE ACTIVATION TESTTEST H-CLATINTER-LABORATORY REPRODUCIBILITYPEPTIDE REACTIVITY ASSAYHUMAN CELL-LINESIN-VITRO ASSAYSHUMAN KERATINOCYTESTEST BATTERYCHEMICALSPOTENCY

식별자

Scopus EID
2-s2.0-85054054237
WoS UID
000448578200010