본문 바로가기

Effect of Cryogenic Temperature on Low-Cycle Fatigue Behavior of AISI 304L Welded Joint

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q3
저널
METALS8(9) · 2018
피인용
Web of Science 11Scopus 12
FWCI (Scopus)
0.11
JCR IF
JCR 2017 1.704
ISSN
2075-4701

저자

  1. Oh, Dongjin제1저자Department of Joining Technology, Korea Institute of Materials Science, Changwon, South Korea
  2. Song, SangwooDepartment of Joining Technology, Korea Institute of Materials Science, Changwon, South Korea
  3. Kim, NamkyuDepartment of Joining Technology, Korea Institute of Materials Science, Changwon, South Korea
  4. 김명현교신저자Department of Naval Architecture and Ocean Engineering, Pusan National University, Busan, South Korea

초록

The aim of this study is to investigate the low-cycle fatigue (LCF) properties of an AISI 304L welded joint based on experimental data. The influential parameters on the LCF such as the specimen thickness, strain ratio and cryogenic temperature were considered in this experimental study. In order to investigate the thickness effect on the LCF behavior, two types of specimens with thicknesses of 5 mm and 10 mm were used in an LCF test. In addition, the fatigue tests were conducted under strain control with three different strain ratios of R = -1, 0, and 0.5 at room and cryogenic temperatures. Based on the results obtained by this experimental study, no significant effect involved with the thickness and the strain ratio were observed. However, it was clearly observed that LCF performance at room temperature is lower than that at cryogenic temperature. Finally, an LCF design curve that can be used in design of the liquefied natural gas (LNG) applications is suggested.

키워드

low-cycle fatiguewelded jointstrain ratiothickness effectcryogenic temperatureSTAINLESS-STEEL 304LMARTENSITIC-TRANSFORMATIONSTRENGTHLIFEDEFORMATIONALLOY

식별자

Scopus EID
2-s2.0-85052605294
WoS UID
000448144400004