본문 바로가기

Direct Thermal Growth of Large Scale Cl-doped CdTe Film for Low Voltage High Resolution X-ray Image Sensor

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
SCIENTIFIC REPORTS8 · 2018
피인용
Web of Science 25Scopus 29
FWCI (Scopus)
0.54
JCR IF
JCR 2017 4.122
ISSN
2045-2322

저자

  1. Lee, Silah제1저자Department of Physics and Institute of Physics and Applied Physics, Yonsei University, Seoul, South Korea
  2. Kim, Jin SungDepartment of Physics and Institute of Physics and Applied Physics, Yonsei University, Seoul, South Korea
  3. Ko, Kyeong RokDepartment of Physics and Institute of Physics and Applied Physics, Yonsei University, Seoul, South Korea
  4. Lee, Gun HwanDepartment Of Surface Technology, Korea Institute of Materials Science (KIMS), 797 Changwon-daero, Seongsan-gu, Changwon-si, South Korea
  5. Lee, Dong JinRayence Co.,Ltd, 14, Samsung 1-ro 1-gil, Hwaseong-si, South Korea
  6. Kim, Dong wookRayence Co.,Ltd, 14, Samsung 1-ro 1-gil, Hwaseong-si, South Korea
  7. Kim, Jin EuiRayence Co.,Ltd, 14, Samsung 1-ro 1-gil, Hwaseong-si, South Korea
  8. 김호경School of Mechanical Engineering, Pusan National University, Geumjeong-gu, South Korea
  9. 김동운School of Mechanical Engineering, Pusan National University, Geumjeong-gu, South Korea
  10. Im, Seongil교신저자Department of Physics and Institute of Physics and Applied Physics, Yonsei University, Seoul, South Korea

초록

Polycrystalline cadmium telluride (CdTe) X-ray photodetector with advanced performance was fabricated in a Schottky diode form by direct thermal deposition (evaporation) on pixelized complementary metal oxide semiconductor (CMOS) readout panel. Our CdTe X-ray detector shows such a variety of benefits as relatively low process temperature, low cost, low operation voltage less than 40 V, and higher sensitivity and spatial resolution than those of commercial a-Se detectors. CdTe has cubic Zinc Blende structure and maintains p-type conduction after growth in general. For low voltage operation, we succeeded in Cl doping at all stage of CdTe film deposition, and as a result, hole concentration of p-type CdTe was reduced to similar to 10(12) cm(-3) from similar to 10(15) cm(-3), and such concentration reduction could enable our Schottky diode with Ti electrode to operate at a reverse bias of less than 40 V. Our CdTe Schottky diode/CMOS pixel array as a direct conversion type imager demonstrates much higher resolution X-ray imaging in 7 x 9 cm(2) large scale than that of CsI/CMOS array, an indirect conversion imager. To our limited knowledge, our results on polycrystalline CdTe Schottky diode/CMOS array would be very novel as a first demonstration of active pixel sensor system equipped with directly deposited large scale X-ray detector.

키워드

FLAT-PANEL DETECTORACTIVE PIXEL SENSORDIGITAL RADIOGRAPHYAMORPHOUS SELENIUMSPATIAL-RESOLUTIONMAMMOGRAPHYPERFORMANCEEXPANSIONPROTOTYPEPHOTOCONDUCTORS