Direct Thermal Growth of Large Scale Cl-doped CdTe Film for Low Voltage High Resolution X-ray Image Sensor
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- SCIENTIFIC REPORTS8 · 2018
- 피인용
- Web of Science 25Scopus 29
- FWCI (Scopus)
- 0.54
- JCR IF
- JCR 2017 4.122
- ISSN
- 2045-2322
저자
- Lee, Silah제1저자Department of Physics and Institute of Physics and Applied Physics, Yonsei University, Seoul, South Korea
- Kim, Jin SungDepartment of Physics and Institute of Physics and Applied Physics, Yonsei University, Seoul, South Korea
- Ko, Kyeong RokDepartment of Physics and Institute of Physics and Applied Physics, Yonsei University, Seoul, South Korea
- Lee, Gun HwanDepartment Of Surface Technology, Korea Institute of Materials Science (KIMS), 797 Changwon-daero, Seongsan-gu, Changwon-si, South Korea
- Lee, Dong JinRayence Co.,Ltd, 14, Samsung 1-ro 1-gil, Hwaseong-si, South Korea
- Kim, Dong wookRayence Co.,Ltd, 14, Samsung 1-ro 1-gil, Hwaseong-si, South Korea
- Kim, Jin EuiRayence Co.,Ltd, 14, Samsung 1-ro 1-gil, Hwaseong-si, South Korea
- 김호경School of Mechanical Engineering, Pusan National University, Geumjeong-gu, South Korea
- 김동운School of Mechanical Engineering, Pusan National University, Geumjeong-gu, South Korea
- Im, Seongil교신저자Department of Physics and Institute of Physics and Applied Physics, Yonsei University, Seoul, South Korea
초록
Polycrystalline cadmium telluride (CdTe) X-ray photodetector with advanced performance was fabricated in a Schottky diode form by direct thermal deposition (evaporation) on pixelized complementary metal oxide semiconductor (CMOS) readout panel. Our CdTe X-ray detector shows such a variety of benefits as relatively low process temperature, low cost, low operation voltage less than 40 V, and higher sensitivity and spatial resolution than those of commercial a-Se detectors. CdTe has cubic Zinc Blende structure and maintains p-type conduction after growth in general. For low voltage operation, we succeeded in Cl doping at all stage of CdTe film deposition, and as a result, hole concentration of p-type CdTe was reduced to similar to 10(12) cm(-3) from similar to 10(15) cm(-3), and such concentration reduction could enable our Schottky diode with Ti electrode to operate at a reverse bias of less than 40 V. Our CdTe Schottky diode/CMOS pixel array as a direct conversion type imager demonstrates much higher resolution X-ray imaging in 7 x 9 cm(2) large scale than that of CsI/CMOS array, an indirect conversion imager. To our limited knowledge, our results on polycrystalline CdTe Schottky diode/CMOS array would be very novel as a first demonstration of active pixel sensor system equipped with directly deposited large scale X-ray detector.
키워드
FLAT-PANEL DETECTORACTIVE PIXEL SENSORDIGITAL RADIOGRAPHYAMORPHOUS SELENIUMSPATIAL-RESOLUTIONMAMMOGRAPHYPERFORMANCEEXPANSIONPROTOTYPEPHOTOCONDUCTORS
식별자
- Scopus EID
- 2-s2.0-85054463072
- WoS UID
- 000446325500022



로그인
연구물 목록으로