본문 바로가기

Diagnostic Performance of Technetium-99m Methoxy-Isobutyl-Isonitrile for Differentiation of Malignant Thyroid Nodules: A Systematic Review and Meta-Analysis

문서 유형
연구출판물 · 리뷰논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
THYROID28(10) · pp.1339 · 2018
피인용
Web of Science 15Scopus 14
FWCI (Scopus)
0.51
JCR IF
JCR 2017 7.557
ISSN
1050-7256

저자

  1. 김성장제1저자교신저자Department of Nuclear Medicine, Pusan National University Yangsan Hospital, Yangsan-si, Gyeongsangnam-do, South Korea
  2. Lee, Sang-WooDepartment of Nuclear Medicine, Kyungpook National University Medical Center and School of Medicine, Daegu, South Korea
  3. Jeong, Shin YoungDepartment of Nuclear Medicine, Kyungpook National University Medical Center and School of Medicine, Daegu, South Korea
  4. 박경준Department of Nuclear Medicine and Biomedical Research Institute, Pusan National University Hospital, Busan, South Korea
  5. 김근영Department of Nuclear Medicine and Biomedical Research Institute, Pusan National University Hospital, Busan, South Korea

초록

Background: The purpose of the current study was to investigate the diagnostic performance of technetium-99m (Tc-99m) methoxy-isobutyl-isonitrile (MIBI) for differentiation of malignant thyroid nodules (TN) through a systematic review and meta-analysis. Methods: The MEDLINE/PubMed and EMBASE database, from the earliest available date of indexing through January 31, 2018, were searched for studies evaluating the diagnostic performance of Tc-99m MIBI for TN. The sensitivities and specificities were determined across studies, positive and negative likelihood ratios (LR+ and LR-) were calculated, and summary receiver operating characteristic curves were constructed. Results: Across 22 studies (2421 patients), the pooled sensitivity for Tc-99 m MIBI thyroid scan was 0.87 [confidence interval (CI) 0.76-0.93] with heterogeneity (I-2 = 92.3) and a pooled specificity of 0.78 [CI 0.67-0.86] with heterogeneity (I-2 = 96.4). LR syntheses gave an overall LR+ of 4.0 [CI 2.5-6.3] and LR- of 0.17 [CI 0.09-0.32]. The pooled diagnostic odds ratio was 24 [CI 63-176]. The hierarchical summary receiver operating characteristic curve indicates that the area under the curve was 0.90 [CI 0.87-0.92]. In meta-regression analysis, no definite variable was the source of the study heterogeneity. Conclusion: The current meta-analysis shows a moderate sensitivity and specificity of Tc-99 m MIBI thyroid scan for differentiation of malignant TN. However, the diagnostic odds ratio was relatively low and the LR scattergram indicated that Tc-99m MIBI thyroid scan is not useful for confirming the presence of malignant TN or for its exclusion. Therefore, Tc-99m MIBI thyroid scans should be used restrictively and interpreted cautiously when assessing TN for malignancy.

키워드

Tc-99m MIBIthyroidnodulesthyroid cancerFINE-NEEDLE-ASPIRATIONTEST ACCURACYMETHOXYISOBUTYLISONITRILE SCINTIGRAPHYMYOCARDIAL VIABILITYMIBISOLITARYCYTOLOGYCANCERULTRASONOGRAPHYMANAGEMENT

식별자

Scopus EID
2-s2.0-85054067834
WoS UID
000445635400014