본문 바로가기

Effect of EOG Signal Filtering on the Removal of Ocular Artifacts and EEG-Based Brain-Computer Interface: A Comprehensive Study

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
저널
COMPLEXITY2018 · 2018
피인용
Web of Science 35Scopus 47
FWCI (Scopus)
1.23
JCR IF
JCR 2017 1.829
ISSN
1076-2787

저자

  1. 만난 말리크 무하마드 나임제1저자Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
  2. 카므란 아흐마드 무하마드Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
  3. Kang, ShinilNational Center for Optically-Assisted Ultrahigh-precision Mechanical Systems, Yonsei University, Seoul, South Korea
  4. 정명영교신저자Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea

초록

It is a fact that contamination of EEG by ocular artifacts reduces the classification accuracy of a brain-computer interface (BCI) and diagnosis of brain diseases in clinical research. Therefore, for BCI and clinical applications, it is very important to remove/reduce these artifacts before EEG signal analysis. Although, EOG-based methods are simple and fast for removing artifacts but their performance, meanwhile, is highly affected by the bidirectional contamination process. Some studies emphasized that the solution to this problem is low-pass filtering EOG signals before using them in artifact removal algorithm but there is still no evidence on the optimal low-pass frequency limits of EOG signals. In this study, we investigated the optimal EOG signal filtering limits using state-of-the-art artifact removal techniques with fifteen artificially contaminated EEG and EOG datasets. In this comprehensive analysis, unfiltered and twelve different low-pass filtering of EOG signals were used with five different algorithms, namely, simple regression, least mean squares, recursive least squares, REGICA, and AIR Results from statistical testing of time and frequency domain metrics suggested that a low-pass frequency between 6 and 8Hz could be used as the most optimal filtering frequency of EOG signals, both to maximally overcome/minimize the effect of bidirectional contamination and to achieve good results from artifact removal algorithms. Furthermore, we also used BCI competition IV datasets to show the efficacy of the proposed framework on real EEG signals. The motor-imagery-based BCI achieved statistically significant high-classification accuracies when artifacts from EEG were removed by using 7Hz low-pass filtering as compared to all other filterings of EOG signals. These results also validated our hypothesis that low-pass filtering should be applied to EOG signals for enhancing the performance of each algorithm before using them for artifact removal process. Moreover, the comparison results indicated that the hybrid algorithms outperformed the performance of single algorithms for both simulated and experimental EEG datasets.

키워드

INDEPENDENT COMPONENT ANALYSISNEAR-INFRARED SPECTROSCOPYEYE-MOVEMENTSMOTOR IMAGERYELECTROENCEPHALOGRAMREGRESSIONSUPPRESSIONALGORITHMCLASSIFICATIONMINIMIZATION

식별자

Scopus EID
2-s2.0-85062014532
WoS UID
000438805200001