Pumpless Microflow Cytometry Enabled by Viscosity Modulation and Immunobead Labeling
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- Nature IndexSCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- ANALYTICAL CHEMISTRY90(13) · pp.8254 · 2018
- 피인용
- Web of Science 8Scopus 9
- FWCI (Scopus)
- 0.35
- JCR IF
- JCR 2017 6.042
- ISSN
- 0003-2700
저자
- Kim, Byeongyeon제1저자Department of Biomedical Engineering, Kyung Hee University, 17104, Yongin-si Gyeonggi-do, South Korea
- Oh, SeinDepartment of Biomedical Engineering, Kyung Hee University, 17104, Yongin-si Gyeonggi-do, South Korea
- Shin, SuyeonDepartment of Biomedical Engineering, Kyung Hee University, 17104, Yongin-si Gyeonggi-do, South Korea
- 임상구Department of Biomaterials Science, Life and Industry Convergence Institute, Pusan National University, Miryang, South Korea
- 양승윤Department of Biomaterials Science, Life and Industry Convergence Institute, Pusan National University, Miryang, South Korea
- Hahn, Young Ki교신저자Department of New Biology, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, South Korea
- Choi, SungyoungDepartment of Biomedical Engineering, Kyung Hee University, 17104, Yongin-si Gyeonggi-do, South Korea
초록
Major challenges of miniaturizing flow cytometry include obviating the need for bulky, expensive, and complex pump-based fluidic and laser-based optical systems while retaining the ability to detect target cells based on their unique surface receptors. We addressed these critical challenges by (i) using a viscous liquid additive to control flow rate passively, without external pumping equipment, and (ii) adopting an immunobead assay that can be quantified with a portable fluorescence cell counter based on a blue light-emitting diode. Such novel features enable pumpless microflow cytometry (pFC) analysis by simply dropping a sample solution onto the inlet reservoir of a disposable cell-counting chamber. With our pFC platform, we achieved reliable cell counting over a dynamic range of 9-298 cells/mu L. We demonstrated the practical utility of the platform by identifying a type of cancer cell based on CD326, the epithelial cell adhesion molecule. This portable microflow cytometry platform can be applied generally to a range of cell types using immunobeads labeled with specific antibodies, thus making it valuable for cell-based and point-of-care diagnostics.
키워드
CIRCULATING TUMOR-CELLSFLOW-CYTOMETRYSTEM-CELLSSHEATHLESSSORTER
식별자
- Scopus EID
- 2-s2.0-85048362515
- WoS UID
- 000438008600064



로그인
연구물 목록으로