A novel sensor-based assessment of lower limb spasticity in children with cerebral palsy
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 피인용
- Web of Science 37Scopus 47
- FWCI (Scopus)
- 1.89
- JCR IF
- JCR 2017 3.865
- ISSN
- 1743-0003
저자
- Choi, Seoyoung제1저자Department of Robotics Engineering, DGIST (Daegu Gyeongbuk Institute of Science and Technology), Daegu, South Korea
- 신용범Department of Rehabilitation Medicine, Pusan National University, School of Medicine, Biomedical Research Institute, Pusan National University Hospital, Busan, South Korea
- 김수연Department of Rehabilitation Medicine, Pusan National University Yangsan Hospital, Yangsan, South Korea
- Kim, Jonghyun교신저자Department of Robotics Engineering, DGIST (Daegu Gyeongbuk Institute of Science and Technology), Daegu, South Korea
초록
Background: To provide effective interventions for spasticity, accurate and reliable spasticity assessment is essential. For the assessment, the Modified Tardieu Scale (MTS) has been widely used owing to its simplicity and convenience. However, it has poor or moderate accuracy and reliability. Methods: We proposed a novel inertial measurement unit (IMU)-based MTS assessment system to improve the accuracy and reliability of the MTS itself. The proposed system consists of a joint angle calculation algorithm, a function to detect abnormal muscle reaction (a catch and clonus), and a visual biofeedback mechanism. Through spastic knee and ankle joint assessment, the proposed IMU-based MTS assessment system was compared with the conventional MTS assessment system in 28 children with cerebral palsy by two raters. Results: The results showed that the proposed system has good accuracy (root mean square error < 3.2 degrees) and test-retest and inter-rater reliabilities (ICC > 0.8), while the conventional MTS system has poor or moderate reliability. Moreover, we found that the deteriorated reliability of the conventional MTS system comes from its goniometric measurement as well as from irregular passive stretch velocity. Conclusions: The proposed system, which is clinically relevant, can significantly improve the accuracy and reliability of the MTS in lower limbs for children with cerebral palsy.
키워드
AccuracyAssessmentCerebral palsyInertia measurement unit (IMU)Joint angleModified Tardieu scaleReliabilitySpasticityBODY SEGMENT ORIENTATIONMODIFIED TARDIEU SCALETOXIN TYPE-ACONSENSUS STATEMENTEUROPEAN CONSENSUSASHWORTH SCALERELIABILITYMOVEMENTMOTIONACCELEROMETER
식별자
- Scopus EID
- 2-s2.0-85048014809
- WoS UID
- 000434089100001



로그인
연구물 목록으로