Diagnostic accuracy of F-18-FDG PET or PET/CT for the characterization of adrenal masses: a systematic review and meta-analysis
Diagnostic accuracy of 18F-FDG PET or PET/CT for the characterization of adrenal masses: A systematic review and meta-analysis
- 문서 유형
- 연구출판물 · 리뷰논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q3Scopus Q2
- 저널
- BRITISH JOURNAL OF RADIOLOGY91(1086) · 2018
- 피인용
- Web of Science 54Scopus 65
- FWCI (Scopus)
- 1.33
- JCR IF
- JCR 2017 1.814
- ISSN
- 0007-1285
저자
- 김성장제1저자교신저자Department of Nuclear Medicine, Pusan National University Yangsan Hospital, Yangsan, South Korea
- Lee, Sang-WooDepartment of Nuclear Medicine, Kyungpook National University Medical Center, School of Medicine, Daegu, South Korea
- 박경준Department of Nuclear Medicine and Biomedical Research Institute, Pusan National University Hospital, Busan, South Korea
- 김인주Department of Nuclear Medicine and Biomedical Research Institute, Pusan National University Hospital, Busan, South Korea
- 김근영Department of Nuclear Medicine and Biomedical Research Institute, Pusan National University Hospital, Busan, South Korea
초록
Objective: We aimed to explore the role of the diagnostic accuracy of F-18 fluodeoxyglucose PET (F-18-FDG PET) or PET/CT for characterization of adrenal lesions through a systematic review and meta-analysis. Methods: The MEDLINE, EMBASE, and Cochrane Library database, from the earliest available date of indexing through 30 April 2017, were searched for studies evaluating the diagnostic performance of F-18-FDG PET or PET/CT for characterization of adrenal lesions. We determined the sensitivities and specificities across studies, calculated positive and negative likelihood ratios (LR+ and LR-), and constructed summary receiver operating characteristic curves. Results: Across 29 studies (2421 patients), the pooled sensitivity for F-18-FDG PET or PET/CT was 0.91 [95% CI (0.88-0.94)] with heterogeneity (chi(2) = 141.8, p = 0.00) and a pooled specificity of 0.91 [95% CI (0.87-0.93)] with heterogeneity (chi(2) = 113.7, p = 0.00). Likelihood ratio (LR) syntheses gave an overall positive likelihood ratio (LR+) of 9.9 [95% CI (7.1-13.7)] and negative likelihood ratio (LR-) of 0.09 [95% CI (0.07-0.13)]. The pooled diagnostic odds ratio was 105 [95% CI (63-176)]. In metaregression analysis, study design, publication year, study location (western vs others), interpretation criteria of PET or PET/CT images, quantification of PET or PET/CT [SUVmax (maximum standardized uptake value) vs SUV (standardized uptake value) ratio], patient group, and analysis method (patient-based vs lesion-based) were the sources of the study heterogeneity. However, in multivariate metaregression, no definite variable was the source of the study heterogeneity. Conclusion: F-18-FDG PET or PET/CT demonstrated good sensitivity and specificity for the characterization of adrenal masses. At present, the literature regarding the use of F-18-FDG PET or PET/CT for the characterization of adrenal masses remains still limited; thus, further large multicenter studies would be necessary to substantiate the diagnostic accuracy of F-18-FDG PET or PET/CT characterization of adrenal masses. Advances in knowledge: F-18-FDG PET or PET/CT showed good sensitivity and specificity for the characterization of adrenal masses and could provide additional information for that purpose.
키워드
EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHYLUNG-CANCER PATIENTSDELAYED ENHANCED CTFDG-PET/CTDIFFERENTIAL-DIAGNOSISMALIGNANT LESIONSCHEMICAL-SHIFTUNENHANCED CTBENIGNEXPERIENCE
식별자
- Scopus EID
- 2-s2.0-85047907363
- WoS UID
- 000433989200005



로그인
연구물 목록으로