본문 바로가기

Bruch's membrane opening-minimum rim width and visual field loss in glaucoma: a broken stick analysis

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q4Scopus Q3
저널
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY11(5) · pp.828 · 2018
피인용
Web of Science 10Scopus 12
FWCI (Scopus)
1.03
JCR IF
JCR 2017 1.166
ISSN
2222-3959

저자

  1. 박건형제1저자Department of Ophthalmology, Pusan National University College of Medicine, Busan, China
  2. 이지웅교신저자Department of Ophthalmology, Pusan National University College of Medicine, Busan, China
  3. 김진미Department of Biostatistics, Clinical Trial Center, Biomedical Research Institute, Pusan National University Hospital, Busan, China
  4. Nouri-Mahdavi, KourosStein Eye Institute, David Geffen School of Medicine at UCLA, Los Angeles, United States
  5. Caprioli, JosephStein Eye Institute, David Geffen School of Medicine at UCLA, Los Angeles, United States

초록

AIM: To determine the Bruch's membrane opening-minimum rim width (BMO-MRW) tipping point where corresponding visual field (VF) damages become detectable. METHODS: A total of 85 normal subjects and 83 glaucoma patients (one eye per participant) were recruited for the study. All of the patients had VF examinations and spectral-domain optical coherence tomography to measure the BMO-MRW. Total deviation values for 52 VF points were allocated to the corresponding sector according to the Garway-Heath distribution map. To evaluate the relationship between VF loss and BMOMRW measurements, a "broken-stick" statistical model was used. The tipping point where the VF values started to sharply decrease as a function of BMO-MRW measurements was estimated and the slopes above and below this tipping point were compared. RESULTS: A 25.9% global BMO-MRW loss from normative value was required for the VF loss to be detectable. Sectorally, substantial BMO-MRW thinning in inferotemporal sector (33.1%) and relatively less BMO-MRW thinning in the superotemporal sector (8.9%) were necessary for the detection of the VF loss. Beyond the tipping point, the slopes were close to zero throughout all of the sectors and the VF loss was unrelated to the BMO-MRW loss. The VF loss was related to the BMO-MRW loss below the tipping point. The difference between the two slopes was statistically significant (P= 0.002). CONCLUSION: Substantial BMO-MRW loss appears to be necessary for VF loss to be detectable in patients with open angle glaucoma with standard achromatic perimetry.

키워드

Bruch's membrane opening-minimum rim widthvisual field lossstructure function relationshipbroken stick modeloptical coherence tomographyNERVE-FIBER LAYEROPTICAL COHERENCE TOMOGRAPHYLASER OPHTHALMOSCOPY ANCILLARYOCULAR HYPERTENSION TREATMENTNORMAL-TENSION GLAUCOMADISC MARGIN ANATOMYOPEN-ANGLE GLAUCOMATHICKNESS MEASUREMENTSEYESPROGRESSION

식별자

Scopus EID
2-s2.0-85050382326
WoS UID
000433246500019