본문 바로가기

Critical bounds on noise and SNR for robust estimation of real-time brain activity from functional near infra-red spectroscopy

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
NEUROIMAGE176 · pp.321 · 2018
피인용
Web of Science 4Scopus 4
FWCI (Scopus)
0.15
JCR IF
JCR 2017 5.426
ISSN
1053-8119

저자

  1. Aqil, Muhammad제1저자Department of Electrical Engineering, Pakistan Institute of Engineering and Applied Sciences, Islamabad, Pakistan
  2. 정명영교신저자Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea

초록

The robust characterization of real-time brain activity carries potential for many applications. However, the contamination of measured signals by various instrumental, environmental, and physiological sources of noise introduces a substantial amount of signal variance and, consequently, challenges real-time estimation of contributions from underlying neuronal sources. Functional near infra-red spectroscopy (fNIRS) is an emerging imaging modality whose real-time potential is yet to be fully explored. The objectives of the current study are to (i) validate a time-dependent linear model of hemodynamic responses in fNIRS, and (ii) test the robustness of this approach against measurement noise (instrumental and physiological) and mis-specification of the hemodynamic response basis functions (amplitude, latency, and duration). We propose a linear hemodynamic model with timevarying parameters, which are estimated (adapted and tracked) using a dynamic recursive least square algorithm. Owing to the linear nature of the activation model, the problem of achieving robust convergence to an accurate estimation of the model parameters is recast as a problem of parameter error stability around the origin. We show that robust convergence of the proposed method is guaranteed in the presence of an acceptable degree of model misspecification and we derive an upper bound on noise under which reliable parameters can still be inferred. We also derived a lower bound on signal-to-noise-ratio over which the reliable parameters can still be inferred from a channel/ voxel. Whilst here applied to fNIRS, the proposed methodology is applicable to other hemodynamicbased imaging technologies such as functional magnetic resonance imaging.

키워드

Real-time brain imagingNear-infrared spectroscopy (NIRS)Misspecification (delay and dispersion) of hemodynamic responsePhysiological noisesRobustness bound of RLS adaptationSignal-to-noise ratio (SNR) bound for fNIRS estimationRECURSIVE LEAST-SQUARESGENERAL LINEAR-MODELHEMODYNAMIC-RESPONSENIRSFMRITOMOGRAPHYACTIVATIONSYNCHRONIZATIONACCURACYSIGNALS

식별자

Scopus EID
2-s2.0-85046696682
WoS UID
000433223700028