본문 바로가기

Ultra-low-dose lung screening CT with model-based iterative reconstruction: an assessment of image quality and lesion conspicuity

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q3Scopus Q2
저널
ACTA RADIOLOGICA59(5) · pp.553 · 2018
피인용
Web of Science 5Scopus 12
FWCI (Scopus)
0.51
JCR IF
JCR 2017 1.823
ISSN
0284-1851

저자

  1. Ju, Yun Hye제1저자Biomedical Engineering, Yonsei University, Wonju, South Korea
  2. 이기원Department of Radiology, Pusan National University Hospital, Busan, South Korea
  3. 이지원ADepartment of Radiology, Pusan National University Hospital, Busan, South Korea
  4. 홍승백Department of Radiology, Pusan National University Hospital, Busan, South Korea
  5. Suh, Young JuDepartment of Biomedical Sciences, School of Medicine, Inha University, Incheon, South Korea
  6. 정연주교신저자Department of Radiology, Pusan National University Hospital, Busan, South Korea

초록

Background: Reducing radiation dose inevitably increases image noise, and thus, it is important in low-dose computed tomography (CT) to maintain image quality and lesion detection performance. Purpose: To assess image quality and lesion conspicuity of ultra-low-dose CT with model-based iterative reconstruction (MBIR) and to determine a suitable protocol for lung screening CT. Material and Methods: A total of 120 heavy smokers underwent lung screening CT and were randomly and equally assigned to one of five groups: group 1 = 120 kVp, 25 mAs, with FBP reconstruction; group 2 = 120 kVp, 10 mAs, with MBIR; group 3 = 100 kVp, 15 mAs, with MBIR; group 4 = 100 kVp, 10 mAs, with MBIR; and group 5 = 100 kVp, 5 mAs, with MBIR. Two radiologists evaluated intergroup differences with respect to radiation dose, image noise, image quality, and lesion conspicuity using the Kruskal-Wallis test and the Chi-square test. Results: Effective doses were 61-87% lower in groups 2-5 than in group 1. Image noises in groups 1 and 5 were significantly higher than in the other groups (P < 0.001). Overall image quality was best in group 1, but diagnostic acceptability of overall image qualities in groups 1-3 was not significantly different (all P values > 0.05). Lesion conspicuities were similar in groups 1-4, but were significantly poorer in group 5. Conclusion: Lung screening CT with MBIR obtained at 100 kVp and 15 mAs enables a similar to 60% reduction in radiation dose versus low-dose CT, while maintaining image quality and lesion conspicuity.

키워드

Computed tomography (CT)ultra-low-dose CTlung screeningiterative reconstructionimage qualityradiation doseRADIATION-EXPOSURECHEST

식별자

Scopus EID
2-s2.0-85044151690
WoS UID
000429744900007