The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q3Scopus Q2
피인용
Web of Science 42Scopus 52
FWCI (Scopus)
1.49
JCR IF
JCR 2017 1.61
ISSN
1749-799X

저자

  1. 박양수제1저자Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Department of Orthopedics, Yangsan, South Korea
  2. 신원철Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Department of Orthopedics, Yangsan, South Korea
  3. 이상민Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Department of Orthopedics, Yangsan, South Korea
  4. 곽상호Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Department of Orthopedics, Yangsan, South Korea
  5. 배정연Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Department of Orthopedics, Yangsan, South Korea
  6. 서근택교신저자Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Department of Orthopedic Surgery, Yangsan, Gyeongsangnam-do, South Korea

초록

Background: Several radiological methods for measuring the anteversion of the acetabular component after total hip arthroplasty (THA) exist, and no single standardized method has been established. We evaluated the reliability and accuracy of six widely utilized methods (Liaw et al., Lewinnek et al., Widmer, Hassan et al., Ackland et al., and Woo and Morrey) for measuring anteversion on plain radiographs, using a reference standard in the same definition obtained from the PolyWare programme. Methods: We reviewed 71 patients who underwent primary unilateral THA. The anteversion of the acetabular component was measured on pelvis AP radiographs using five different methods (Liaw et al., Lewinnek et al., Widmer, Hassan et al., and Ackland et al.) and on cross-table lateral radiographs using the method of Woo and Morrey. The values obtained using the PolyWare programme, which determines the anteversion of the acetabular component by edge detection, were regarded as the reference standard. Results: Intra-and inter-observer reliabilities were excellent for all methods using plain radiographs, including the PolyWare programme. The method of Liaw et al. obtained values similar to those obtained using the PolyWare programme and was thus considered accurate (P = 0.447). However, values obtained using the other five methods significantly differed from those obtained using the PolyWare programme and were thus considered less accurate (P < 0.001, P < 0.001, P < 0.001, P = 0.007, and P < 0.001, respectively). Conclusion: The method of Liaw et al. is more accurate than other methods using plain radiographs for the measurement of the anteversion of the acetabular component after THA, with reference to the anteversion obtained from the PolyWare programme.

키워드

AnteversionAcetabular componentPlain radiographTotal hip arthroplastyMEASURING CUP ORIENTATIONPOLYETHYLENE WEARANTEROPOSTERIOR RADIOGRAPHSINTRACLASS CORRELATIONSLATERAL RADIOGRAPHSRELIABILITYREPLACEMENTACCURACYPOSITIONVERSION