Performance of the cobas Hepatitis B virus (HBV) test using the cobas 4800 system and comparison of HBV DNA quantification ability between the COBAS AmpliPrep/COBAS TaqMan HBV test version 2.0 and cobas HBV test
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q1
- 저널
- JOURNAL OF CLINICAL VIROLOGY101 · pp.47 · 2018
- 피인용
- Web of Science 9Scopus 10
- FWCI (Scopus)
- 0.44
- JCR IF
- JCR 2017 3.101
- ISSN
- 1386-6532
저자
- 신경화제1저자Department of Laboratory Medicine, Pusan National University Hospital, Busan, South Korea
- 이현지Department of Laboratory Medicine, Pusan National University Yangsan Hospital, Yangsan, South Korea
- 장철훈Department of Laboratory Medicine, Pusan National University Yangsan Hospital, Yangsan, South Korea
- 김형회교신저자Department of Laboratory Medicine, Pusan National University Hospital, Busan, South Korea
초록
Background: Hepatitis B virus (HBV) DNA levels are used to predict the response to therapy, determine therapy initiation, monitor resistance to therapy, and establish treatment success. Objective: To verify the performance of the cobas HBV test using the cobas 4800 system for HBV DNA quantification and to compare the HBV DNA quantification ability between the cobas HBV test and COBAS AmpliPrep/COBAS TaqMan HBV version 2.0 (CAP/CTM v2.0). Study design: The precision, linearity, and limit of detection of the cobas HBV test were evaluated using the 4th World Health Organization International Standard material and plasma samples. Clinical samples that yielded quantitative results using the CAP/CTM v2.0 and cobas HBV tests were subjected to correlational analysis. Results: Three hundred forty-nine samples were subjected to correlational analysis, among which 114 samples showed results above the lower limit of quantification. Comparable results were obtained ([cobas HBV test] = 1.038 x [CAP/CTM v2.0]-0.173, r = 0.914) in 114 samples, which yielded values above the lower limit of quantification. The results for 86.8% of the samples obtained using the cobas HBV test were within 0.5 log(10) IU/mL of the CAP/CTM v2.0 results. The total precision values against the low and high positive controls were 1.4% (mean level: 2.25 log(10) IU/mL) and 3.2% (mean level: 6.23 log10 IU/mL), respectively. The cobas HBV test demonstrated linearity (1.15-6.75 log(10) IU/mL, y= 0.95 x 6+ 0.17, r(2)= 0.994). Conclusion: The cobas HBV test showed good correlation with CAP/CTM v2.0, and had good precision and an acceptable limit of detection. The cobas HBV test using the cobas 4800 is a reliable method for quantifying HBV DNA levels in the clinical setting.
키워드
Cobas HBV testHepatitis B virusDNA quantificationCorrelation analysisINFECTIONSERUMGUIDELINESTHERAPYASSAY