본문 바로가기

Real-time functional optical-resolution photoacoustic microscopy using high-speed alternating illumination at 532 and 1064 nm

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
JOURNAL OF BIOPHOTONICS11(3) · 2018
피인용
Web of Science 19Scopus 20
FWCI (Scopus)
0.86
JCR IF
JCR 2017 3.768
ISSN
1864-063X

저자

  1. Kang, Heesung제1저자Center for Nano-Bio Measurement, Korea Research Institute of Standards and Science, Daejeon, South Korea
  2. Lee, Sang-Won교신저자Center for Nano-Bio Measurement, Korea Research Institute of Standards and Science, Daejeon, South Korea
  3. 박상민Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
  4. 조순우Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
  5. Lee, Jae YongKorea Research Institute of Standards and Science, Center for Length, Daejeon, South Korea
  6. 김창석Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
  7. Lee, Tae GeolCenter for Nano-Bio Measurement, Korea Research Institute of Standards and Science, Daejeon, South Korea

초록

Optical-resolution photoacoustic microscopy (OR-PAM), which has been widely used and studied as a noninvasive and in vivo imaging technique, can yield high-resolution and absorption contrast images. Recently, metallic nanoparticles and dyes, such as gold nanoparticles, methylene blue, and indocyanine green, have been used as contrast agents of OR-PAM. This study demonstrates real-time functional OR-PAM images with high-speed alternating illumination at 2 wavelengths. To generate 2 wavelengths, second harmonic generation at 532 nm with an LBO crystal and a pump wavelength of 1064 nm is applied at a pulse repetition rate of 300 kHz. For alternating illumination, an electro-optical modulator is used as an optical switch. Therefore, the A-line rate for the functional image is 150 kHz, which is half of the laser repetition rate. To enable fast signal processing and real-time displays, parallel signal processing using a graphics processing unit (GPU) is performed. OR-PAM images of the distribution of blood vessels and gold nanorods in a BALB/c-nude mouse's ear can be simultaneously obtained with 500 x 500 pixels and real-time display at 0.49 fps.

키워드

functional imaginggold nanoparticlehigh-speed alternating illuminationoptical-resolution photoacoustic microscopySTIMULATED RAMAN-SCATTERINGCONTRAST AGENTSTOMOGRAPHYLASERBRAINNANOPARTICLES

식별자

Scopus EID
2-s2.0-85032380456
WoS UID
000426731000026