본문 바로가기

Hybrid ECG-gated versus non-gated 512-slice CT angiography of the aorta and coronary artery: image quality and effect of a motion correction algorithm

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q3Scopus Q2
저널
ACTA RADIOLOGICA59(2) · pp.170 · 2018
피인용
Web of Science 1Scopus 2
FWCI (Scopus)
0
JCR IF
JCR 2017 1.823
ISSN
0284-1851

저자

  1. 이지원A제1저자Department of Radiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea
  2. 김창원Department of Radiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea
  3. 이지원BDepartment of Radiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea
  4. 이한철Department of Cardiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea
  5. 김상필Department of Thoracic and Cardiovascular Surgery, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea
  6. 최범성Pusan National University School of Medicine and Medical Research Institute, Pusan National University Yangsan Hospital, Yangsan, South Korea
  7. 정연주교신저자Department of Radiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea

초록

Background: Using the hybrid electrocardiogram (ECG)-gated computed tomography (CT) technique, assessment of entire aorta, coronary arteries, and aortic valve can be possible using single-bolus contrast administration within a single acquisition. Purpose: To compare the image quality of hybrid ECG-gated and non-gated CT angiography of the aorta and evaluate the effect of a motion correction algorithm (MCA) on coronary artery image quality in a hybrid ECG-gated aorta CT group. Material and Methods: In total, 104 patients (76 men; mean age = 65.8 years) prospectively randomized into two groups (Group 1 = hybrid ECG-gated CT; Group 2 = non-gated CT) underwent wide-detector array aorta CT. Image quality, assessed using a four-point scale, was compared between the groups. Coronary artery image quality was compared between the conventional reconstruction and motion correction reconstruction subgroups in Group 1. Results: Group 1 showed significant advantages over Group 2 in aortic wall, cardiac chamber, aortic valve, coronary ostia, and main coronary arteries image quality (all P < 0.001). All Group 1 patients had diagnostic image quality of the aortic wall and left ostium. The MCA significantly improved the image quality of the three main coronary arteries (P < 0.05). Moreover, per-vessel interpretability improved from 92.3% to 97.1% with the MCA (P = 0.013). Conclusion: Hybrid ECG-gated CT significantly improved the heart and aortic wall image quality and the MCA can further improve the image quality and interpretability of coronary arteries.

키워드

X-ray computed tomographyaortacoronary vesselsradiation dosageECG-triggered imaging techniqueDIAGNOSTIC-ACCURACYDISSECTIONRECONSTRUCTION

식별자

Scopus EID
2-s2.0-85040832498
WoS UID
000425981200007