Hybrid ECG-gated versus non-gated 512-slice CT angiography of the aorta and coronary artery: image quality and effect of a motion correction algorithm
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q3Scopus Q2
- 저널
- ACTA RADIOLOGICA59(2) · pp.170 · 2018
- 피인용
- Web of Science 1Scopus 2
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2017 1.823
- ISSN
- 0284-1851
저자
- 이지원A제1저자Department of Radiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea
- 김창원Department of Radiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea
- 이지원BDepartment of Radiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea
- 이한철Department of Cardiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea
- 김상필Department of Thoracic and Cardiovascular Surgery, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea
- 최범성Pusan National University School of Medicine and Medical Research Institute, Pusan National University Yangsan Hospital, Yangsan, South Korea
- 정연주교신저자Department of Radiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea
초록
Background: Using the hybrid electrocardiogram (ECG)-gated computed tomography (CT) technique, assessment of entire aorta, coronary arteries, and aortic valve can be possible using single-bolus contrast administration within a single acquisition. Purpose: To compare the image quality of hybrid ECG-gated and non-gated CT angiography of the aorta and evaluate the effect of a motion correction algorithm (MCA) on coronary artery image quality in a hybrid ECG-gated aorta CT group. Material and Methods: In total, 104 patients (76 men; mean age = 65.8 years) prospectively randomized into two groups (Group 1 = hybrid ECG-gated CT; Group 2 = non-gated CT) underwent wide-detector array aorta CT. Image quality, assessed using a four-point scale, was compared between the groups. Coronary artery image quality was compared between the conventional reconstruction and motion correction reconstruction subgroups in Group 1. Results: Group 1 showed significant advantages over Group 2 in aortic wall, cardiac chamber, aortic valve, coronary ostia, and main coronary arteries image quality (all P < 0.001). All Group 1 patients had diagnostic image quality of the aortic wall and left ostium. The MCA significantly improved the image quality of the three main coronary arteries (P < 0.05). Moreover, per-vessel interpretability improved from 92.3% to 97.1% with the MCA (P = 0.013). Conclusion: Hybrid ECG-gated CT significantly improved the heart and aortic wall image quality and the MCA can further improve the image quality and interpretability of coronary arteries.
키워드
X-ray computed tomographyaortacoronary vesselsradiation dosageECG-triggered imaging techniqueDIAGNOSTIC-ACCURACYDISSECTIONRECONSTRUCTION
식별자
- Scopus EID
- 2-s2.0-85040832498
- WoS UID
- 000425981200007



로그인
연구물 목록으로